background image

 

Subject to technical changes 11/2016 

 

Seite 1 von 12

 

A.S.T. - Angewandte System Technik GmbH, Mess- und Regeltechnik 

 

 

Data Logger 

ADL 280 RFID 

 

Original 

Operating Manual 

 

 

 

 
 
 
 
 
 
 
 
 

A.S.T. - Angewandte System Technik GmbH, Mess- und Regeltechnik 

 

Marschnerstraße 26 

01307 Dresden 

 

Telefon (03 51) 44 55 30 

Telefax (03 51) 44 55 555 

 

www.ast.de 

Содержание ADL 280 RFID

Страница 1: ... T Angewandte System Technik GmbH Mess und Regeltechnik Data Logger ADL 280 RFID Original Operating Manual A S T Angewandte System Technik GmbH Mess und Regeltechnik Marschnerstraße 26 01307 Dresden Telefon 03 51 44 55 30 Telefax 03 51 44 55 555 www ast de ...

Страница 2: ...Dimensions connections 4 4 Operation oft the appliance ADL 280 RFID 4 4 1 Power supply 4 4 2 Operating controls 5 4 3 Implementation of measurement procedure 7 4 4 Display of measurement results 7 4 5 Switching off the appliance 7 5 Operation of software xks280 7 5 1 Installation of software xks280 7 5 2 Reading out data from Data Logger ADL 280 RFID 7 5 3 Configuration of appliance 9 5 4 Addition...

Страница 3: ...e manufacturer 2 Method of functioning The Data Logger ADL 280 RFID is a reading device designed for use in conjunction with an A S T RFID transponder Power is supplied to the transponder by means of an alternating magnetic field with a frequency of 125 kHz The transmission of commands to the transponder takes place via amplitude modulation of the alternating magnetic field response being accompli...

Страница 4: ...t 85 mm Connection Micro USB 2 0 Type B socket 4 Operation oft the appliance ADL 280 RFID 4 1 Power supply Power is supplied to the Data Logger by means of an integral rechargeable battery If connected up to the USB port of a PC or a USB charger power is supplied via the USB This ensures immediate operating availability even if the battery is flat while also facilitating charging of the integral b...

Страница 5: ...Operating controls and display functions on the Data Logger The pushbutton controls trigger the following functions Pushbutton Action Function Press briefly 5 sec Previous dataset Press and hold 5 sec First dataset beginning of list Press briefly 5 sec Switches on the appliance Performs measurement pressing a second time Press and hold 5 sec Switches off the appliance Press briefly 5 sec Next data...

Страница 6: ...ul the display will contain the following information Figure 4 Anzeige eines Messdatensatzes A S T GmbH ADL 280 RFID frei 495 500 21 01 15 17 32 58 Manufacturer Designation of appliance Enough storage space remaining for dataset Clock time format Hours minutes seconds Date format Day month year Battery display with symbols Total storage space available Power supply via USB Battery topped up Batter...

Страница 7: ...asurement result Figure 4 4 5 Switching off the appliance The appliance is switched off by pressing and holding down the key for longer than 5 seconds or automatically after approximately 2 minutes inactivity 5 Operation of software xks280 5 1 Installation of software xks280 The software package xks280 calls for Microsoft NET Framework 4 Client Profile If this is available on the PC the software c...

Страница 8: ...ut takes place automatically Figure 6 Software xks280 Display of list showing all datasets The internal list can be sorted according to the content of the column by clicking onto the column header The columns are modifiable according to their order by clicking onto them with the mouse and dragging them as required 3 Saving the data a Export to Excel Save in Excel program b as comma separated value...

Страница 9: ...ompletely emptied from the Data Logger ADL 280 RFID by actuating the command button Delete from appliance CAUTION The data should first be saved before pressing the command button Delete from appliance Data deleted from the ADL 280 RFID are irretrievably lost 5 3 Configuration of appliance The appliance is configured by performing the following steps 1 Starting up of software xks280 2 Connection o...

Страница 10: ...ntry of the date and time and activating the command Write data in device Note After the date and time has been successfully altered on the appliance a corresponding message will appear briefly within the status bar of the program window 4 Switchover to Tools window Figure 9 Software xks280 Calling up the tools 5 Selection of language on the Data Logger Figure 10 Software xks280 Selection of langu...

Страница 11: ...s are as follows The Data Logger must be connected up to the PC The transponder must be located within the reading range of the Data Logger The field on the Data Logger must be switched on RF Field button Due to limited power consumption at the USB port charging of the integral battery is interrupted whenever the magnetic field is switched on Figure 11 Software xks280 Tools The following functions...

Страница 12: ...Shielding of magnetic field Remove metallic objects away from the magnetic field Interference affecting magnetic field Eliminate source of interference e g additional RFID reader or move away from surrounding area Insufficient magnetic coupling Vary the distance between the sensor and Data Logger or alter the position of the Data Logger Appliance not detected by the software Contact problems Check...

Отзывы: