background image

6

en | Introduction

Conettix Ethernet Communication Module

2016.08 | 08 | F.01U.266.226

Installation and Operation Guide

Bosch Security Systems, Inc.

2.3

Installation workflow

To install and configure the module, use the workflow below. Follow in sequential order from
top to bottom. Check off each box as you complete a step.

!

Caution!

Always power down the control panel when connecting a module. To power down the control
panel, unplug the transformer and disconnect the battery.

 Plan the installation. Refer to System overview, page 7.

 Set the address switch. Refer to Bus address settings, page 9.

 Install the module. Refer to Mount the module in the enclosure, page 10Mount and wire

the tamper switch (optional), page 10, and Wire to the control panel, page 10.

 Configure the module. Refer to Plug and Play configuration for SDI2 or option bus control

panels, page 13, or Plug and Play configuration for SDI or option bus control panels, page 13,
or Web-based configuration, page 13.

 Verify operation using the LEDs. Refer to Maintenance and troubleshooting LEDs, page 30.

Содержание B426

Страница 1: ...Conettix Ethernet Communication Module B426 en Installation and Operation Guide ...

Страница 2: ......

Страница 3: ... 5 3 Web based configuration 13 5 3 1 Web based configuration log in and use 14 5 3 2 Device Information home page 15 5 3 3 Change and save settings using the web 15 5 3 4 Basic Network Settings page 15 5 3 5 Advanced Network Settings page 20 5 3 6 Panel Address Settings page 21 5 3 7 Encryption and Security Settings page 23 5 3 8 Maintenance page 24 5 3 9 Factory Default page 26 5 3 10 Firmware U...

Страница 4: ... subtle performance degradation to complete device failure Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications Warning Failure to follow these instructions can result in a failure to initiate alarm conditions Bosch Security Systems Inc is not responsible for improperly installed tested...

Страница 5: ...ystems Inc and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly 2 2 Bosch Security Systems Inc product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems Inc website at http www boschsecurity com dat...

Страница 6: ...plug the transformer and disconnect the battery Plan the installation Refer to System overview page 7 Set the address switch Refer to Bus address settings page 9 Install the module Refer to Mount the module in the enclosure page 10 Mount and wire the tamper switch optional page 10 and Wire to the control panel page 10 Configure the module Refer to Plug and Play configuration for SDI2 or option bus...

Страница 7: ... panel and the module 8 ᅳ Ethernet network connection to the Ethernet adapter D6680 ITS D6682 ITS D6686 ITS D6682 shown Ethernet Network Adapter 3 ᅳ B426 9 ᅳ Conettix Ethernet Network Adapter ITS D6682 shown 4 ᅳ Ethernet connection between module and Ethernet network 10 ᅳ Connection from ITS D6682 to the COM4 Port on the Conettix D6600 Communications Receiver Gateway 5 ᅳ Ethernet network Local Are...

Страница 8: ...ered SDI SDI2 or option bus device that provides two way communication with compatible control panels over IPv6 or IPv4 Ethernet networks The B426 on board switch determines the bus address of the device Perform configuration of the B426 through the B426 configuration web pages Additional configuration options include B9512G B8512G B6512 B5512 B4512 B3512 D9412GV4 D7412GV4 v2 xx SDI2 keypad and Re...

Страница 9: ...e value for the module s address The figure below shows the address switch setting for address 1 Refer to the following table for panel specific settings Figure 3 3 Address switch set to address 1 Control panels Switch position Control panel address Bus type Function B9512G B8512G B6512 B5512 B4512 B3512 GV4 Solution 2000 3000 1 1 SDI2 Automation Remote Programming or Reporting B9512G B8512G GV4 S...

Страница 10: ...with mounting bracket installed 2 ᅳ Enclosure 3 ᅳ Mounting screws 3 4 2 Mount and wire the tamper switch optional For B9512G B8512G B6512 B5512 B4512 B3512 and GV4 v 2xx control panels you can connect an enclosure door tamper switch for one module in an enclosure Installing the optional tamper switch for use with a B426 1 Mount the ICP EZTS Cover and Wall Tamper Switch P N F01U009269 into the encl...

Страница 11: ...inal strip and interconnect wiring connectors in series Run the wiring connections from the module to the data bus terminals on the compatible control panel Connect the Ethernet cable to the Ethernet port on the module Figure 4 2 Using terminal strip or interconnect cable wiring GV4 control panel shown Callout ᅳ Description 1 ᅳ SDI2 control panel For SDI control panels wire R Y G B to the SDI bus ...

Страница 12: ...rnet Communication Module 2016 08 08 F 01U 266 226 Installation and Operation Guide Bosch Security Systems Inc 3 ᅳ To Ethernet network 4 ᅳ Terminal strip wiring For complete wiring instructions refer to the control panel documentation ...

Страница 13: ...dress for the control panel if not already set SDI2 control panels use address 1 or 2 option bus control panels use address 134 or 250 2 Connect the module to the control panel bus and apply power 3 Program the control panel communication settings using RPS for SDI2 control panels A Link for option bus control panels or the keypad The control panel stores the module settings and automatically prog...

Страница 14: ... Mozilla Firefox 3 or higher type in the B426 s IP address or hostname and press Enter If Web and Automation Security is enabled on the B426 you must type https instead of http The B426 s Login page opens Figure 5 1 B426 Login page 2 Enter the password default is B42V2 and click Login The Device Information home page opens Refer to Device Information home page page 15 3 Browse to the desired setti...

Страница 15: ...tting conflicts with another configured setting for example the Static IP setting is unavailable when DHCP is enabled The setting conflicts with the address setting for example the Panel Address setting is read only if the address switch is set to anything but 0 The setting is unavailable in the current product release Saving settings using the Web To preserve edited values click the OK button on ...

Страница 16: ...racks computers that connect to the network which prevents two computers from accidentally being configured with the same IP address AutoIP enables dynamic IP addresses to be assigned to a device when the device is started up Whereas DHCP requires a DHCP server AutoIP does not require a server when selecting an IP address A host configured with AutoIP receives an IP address of 169 254 xxx xxx Noti...

Страница 17: ...ter In DHCP mode the default gateway is usually resolved automatically When DHCP AutoIP Enable is set to Yes this parameter cannot be changed Obtain IPv4 DNS Server Address Automatically Default Yes Selection Yes No Setting this parameter to No allows entering the server address Setting this parameter to Yes clears addresses and prevents address entry IPv4 DNS Server IP Address Default 0 0 0 0 Sel...

Страница 18: ...FFF FFFF FFFF FFFF FFFF FFFF FFFF This parameter configures the IPv6 DNS server address A DNS server converts internet domain names or hostnames to their corresponding IP addresses In DHCP mode the default value indicates the DHCP server s default DNS is used To use a custom DNS server in DHCP mode change the parameter to the specified DNS server s IP address The IPv6 DNS address has a hexadecimal...

Страница 19: ...eiver RPS Automation or Remote Security Control Port numbers are assigned in various ways based on three ranges System Ports 0 to 1023 User Ports 1024 to 49151 Dynamic or Private Ports 49152 to 65535 Note In order to limit unwanted traffic select a number above 1023 Legacy TCP Automation Enable Default No Selection Yes No When enabled a single TCP connection with no security is allowed TCP Keep Al...

Страница 20: ...t legacy control panels that communicate using Datagram Mode 0 When Legacy Panel Mode is enabled the module uses the Local Port parameter as both the source port and destination port for communication The control panels that use Legacy Panel Mode are GV2 v7 05 and lower D9412G D7412G D7212G v6 99 and lower DS7400XiV4 Port 77EE Configuration Enable Default No Selections Yes No Yes The network confi...

Страница 21: ...amming traffic to the control panel HTTP Port Number Default 80 Selections 1 to 65535 Use this option to configure the port number for the module web server ARP Cache Timeout Default 600 Selections 1 to 600 in 1 sec increments When the module communicates with any device on a network an entry is added to its ARP table for each of those devices The ARP Cache Timeout defines the number of seconds 1 ...

Страница 22: ...munication Module 2016 08 08 F 01U 266 226 Installation and Operation Guide Bosch Security Systems Inc Figure 5 5 Panel Address Settings page Use this option to select the bus address for the control panel type to which the module is connected ...

Страница 23: ... at the central station receiver and the PC running RPS No All communication through the network module is unencrypted Use this option to enable or disable Advanced Encryption Standard AES encryption on the module For B9512G B8512G B6512 B5512 B4512 B3512 and GV4 v2 xx control panels with Panel Programming Enable set to Yes the module does not enable encryption regardless of the setting AES Key Si...

Страница 24: ...omation Security Default Enable for B9512G B8512G B6512 B5512 B4512 B3512 and GV4 v2 xx control panels Disable for all other control panels Selections Disable Enable This parameter enables enhanced security for Automation and B426 Web Access When enabled HTTPS is applied to B426 Web Access changing the default value of the HTTP port number parameter This setting also enables TLS Security for Autom...

Страница 25: ... with compatible SDI2 only control panels and AMAX 2100 3000 4000 Do not disable Web Access Enable and Panel Programming Enable If both are disabled you cannot configure the module Firmware Upgrade Enable Default No Selections Yes No Yes Allows firmware upgrades to the B426 No Prevents firmware upgrades Enable or disable the ability to upgrade the module s firmware from the Firmware Upgrade config...

Страница 26: ...he factory default settings by clicking on the Factory Default menu Click Cancel to cancel the factory default reset If you select OK all configuration options are returned to the factory default settings Notice Returning the module to its factory default settings might cause the module to terminate the current web browsing session If connected to a compatible SDI2 control panel the control panel ...

Страница 27: ...U 266 226 5 3 10 Firmware Update page To upgrade the firmware in the module select the Firmware Update option from the configuration home page The Firmware Update page opens Figure 5 9 Firmware Update page To proceed with the upgrade click OK A new web page opens that allows you to locate the firmware file and upload it to the module ...

Страница 28: ...cify upgrade file Notice Upgrading the firmware in the module causes the module to terminate the current web browsing session 5 3 11 Exiting the web based configuration pages When you are finished configuring the module select the Save and Execute option The Save and Execute web page opens To save the configuration changes that you made click OK A confirmation message appears ...

Страница 29: ...e Configuration en 29 Bosch Security Systems Inc Installation and Operation Guide 2016 08 08 F 01U 266 226 Figure 5 11 Save and Execute confirmation To exit the configuration web page click Logout and then close the internet browser window ...

Страница 30: ...or state Indicates a bus communication error The module is not receiving commands from the control panel On Steady Trouble state Indicates a trouble condition exists Off LED trouble state Module is not powered or some other trouble condition prohibits the module from controlling the heartbeat LED Tab 6 2 Heartbeat LED descriptions Flash pattern Function RX Receive Flashing Occurs when the module r...

Страница 31: ...quick flashes every 1 sec Internal failure On Steady Off On Steady Tab 6 5 Trouble conditions Notice When the tamper switch is closed all module LEDs are Off 6 1 Show the firmware version To show the firmware version using an LED flash pattern If the optional tamper switch is installed With the enclosure door open activate the tamper switch If the optional tamper switch is NOT installed Momentaril...

Страница 32: ...Maintenance and troubleshooting LEDs Conettix Ethernet Communication Module 2016 08 08 F 01U 266 226 Installation and Operation Guide Bosch Security Systems Inc Figure 6 1 Firmware LED flash patterns example ...

Страница 33: ... Connectors LAN WAN RJ 45 modular port Ethernet Cabling Ethernet cable Category 5 or better unshielded twisted pair Ethernet cable length 100 m 328 ft max length Wiring Data bus wire gauge 18 AWG or 22 AWG Data bus wire length Maximum distance Wire size 150 m 500 ft 0 65 mm 22 AWG 300 m 1000 ft 1 02 mm 18 AWG Browser support Microsoft Internet Explorer Microsoft Windows 7 and higher Mozilla Firefo...

Страница 34: ...ifications Conettix Ethernet Communication Module 2016 08 08 F 01U 266 226 Installation and Operation Guide Bosch Security Systems Inc DS7400XiV4 Version 4 10 or higher Easy Series V3 FPD 7024 Solution 2000 3000 ...

Страница 35: ... the B426 temporarily assumes address 169 254 1 1 for configuration Notice Outside access requires obtaining the public IP address and port mapping from the gateway 8 2 1 Use DHCP to look up the IP address of a network connected module If the module is connected to a network a DHCP Dynamic Host Configuration Protocol server assigns the IP address to the module Looking up the module s IP address on...

Страница 36: ...u do not know the address follow the steps below Using the AutoIP 1 Remove power from the module 2 Disconnect the module from the network 3 Connect the B426 directly to the Ethernet port on a computer power up and wait 60 sec If AutoIP service is enabled on your computer a 169 254 XXX XXX address should now be assigned to your computer 4 Open an internet browser Microsoft Internet Explorer 6 or hi...

Страница 37: ......

Страница 38: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2016 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...

Отзывы: