Conettix Ethernet Communication Module
Configuration | en
13
Bosch Security Systems, Inc.
Installation and Operation Guide
2016.08 | 08 | F.01U.266.226
5
Configuration
You can configure the B426 using one of the methods described in this section for your
control panel type:
–
Plug and Play configuration for SDI2 or option bus control panels, page 13
–
Plug and Play configuration for SDI or option bus control panels, page 13
–
Web-based configuration, page 13 (all compatible control panel types)
5.1
Plug and Play configuration for SDI2 or option bus control
panels
Notice!
Option bus control panels include AMAX 2100/3000/4000 firmware version v1.5 or higher.
By default, when connecting a field replacement B426 to an existing SDI2 or option bus
control panel, the control panel overrides the module settings. To keep custom module
settings when you connect a module to a configured control panel, you must disable Panel
Programming Enable using web-based configuration, prior to connecting to the SDI2 or
option bus.
When connected to a non-default SDI2 or option bus control panel, the control panel
automatically configures a connected module.
1.
Set the address switch to the correct address for the control panel if not already set
(SDI2 control panels use address 1 or 2, option bus control panels use address 134 or
250).
2.
Connect the module to the control panel bus and apply power.
3.
Program the control panel communication settings using RPS for SDI2 control panels, A-
Link for option bus control panels, or the keypad.
The control panel stores the module settings and automatically programs the connected
module. To override automatic module programming, use the web configuration pages to set
the Panel Programming Enable parameter to
NO
before installing.
5.2
Plug and Play configuration for SDI or option bus control
panels
When installing under the following conditions, the B426 needs no further configuration:
–
DHCP is available on your network.
–
AES encryption is not required.
–
Default B426 port settings (UDP on Port 7700) are permitted by the network
administrator.
5.3
Web-based configuration
For installations requiring non-default configuration, use the B426 web-based configuration
pages.
Notice!
When connected to a B9512G/B8512G, B6512/B5512/B4512/B3512, or D9412GV4/
D7412GV4/D7212GV4 control panel, configuration for the module must have the Web Access
Enable option set to Yes in order to access or configure the module over the web.
To use the B426 configuration pages, you need the module's IP address or hostname. Refer to
either:
–
Module hostname, page 35