background image

Important Safeguards

1.

Read, Follow, and Retain Instructions

- All safety and

operating instructions should be read and followed before
operating the unit. Retain instructions for future reference.

2.

Heed Warnings

– Adhere to all warnings on the unit and in

the operating instructions.

3.

Attachments

- Attachments not recommended by the prod-

uct manufacturer should not be used, as they may cause haz-
ards.

4.

Installation Cautions

- Do not place this unit on an unsta-

ble stand, tripod, bracket, or mount. The unit may fall, caus-
ing serious injury to a person and serious damage to the
unit. Use only manufacturer-recommended accessories, or
those sold with the product. Mount the unit per the manu-
facturer's instructions. Appliance and cart combination
should be moved with care. Quick stops, excessive force, or
uneven surfaces may cause the appliance and cart combina-
tion to overturn.

5.

Cleaning

- Unplug the unit from the outlet before cleaning.

Follow any instructions provided with the unit. Generally,
using a damp cloth for cleaning is sufficient. Do not use liq-
uid cleaners or aerosol cleaners.

6.

Servicing

- Do not attempt to service this unit yourself.

Opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified ser-
vice personnel.

7.

Damage Requiring Service

- Unplug the unit from the

main AC power source and refer servicing to qualified ser-
vice personnel under the following conditions:
• When the power supply cord or plug is damaged.
• If liquid has been spilled or an object has fallen into the

unit.

• If the unit has been exposed to water and/or inclement

weather (rain, snow, etc.).

• If the unit does not operate normally, when following the

operating instructions. Adjust only those controls specified
in the operating instructions. Improper adjustment of other
controls may result in damage, and require extensive work
by a qualified technician to restore the unit to normal
operation.

• If the unit has been dropped or the cabinet damaged.
• If the unit exhibits a distinct change in performance, this

indicates that service is needed.

8.

Replacement Parts

- When replacement parts are required,

the service technician should use replacement parts specified
by the manufacturer, or that have the same characteristics as
the original part. Unauthorized substitutions may result in
fire, electrical shock, or other hazards.

9.

Safety Check

- Upon completion of servicing or repairs to

the unit, ask the service technician to perform safety checks
to ensure proper operating condition.

10.

Power Sources

- Operate the unit only from the type of

power source indicated on the label. If unsure of the type of
power supply to use, contact your dealer or local power
company. 
• For units intended to operate from battery power, refer to

the operating instructions. 

• For units intended to operate 

with External Power

Supplies

, use only the recommended approved power

supplies. 

• For units intended to operate with a limited power source,

this power source must comply with EN60950.
Substitutions may damage the unit or cause fire or shock.

• For units intended to operate at 24 VAC, normal input

voltage is 

24 VAC

. Voltage applied to the unit's power

input should not exceed 30 VAC. User-supplied wiring,
from the 24 VAC supply to unit, must be in compliance
with electrical codes (Class 2 power levels). Do not ground
the 24 VAC supply at the terminals or at the unit's power
supply terminals.

11.

Coax Grounding

- If an outside cable system is connected

to the unit, ensure that the cable system is grounded. U.S.A.
models only--Section 810 of the National Electrical Code,
ANSI/NFPA No.70, provides information regarding proper
grounding of the mount and supporting structure, grounding
of the coax to a discharge unit, size of grounding conductors,
location of discharge unit, connection to grounding elec-
trodes, and requirements for the grounding electrode.

12.

Grounding or Polarization

- This unit may be equipped

with a polarized alternating current line plug (a plug with
one blade wider than the other). This safety feature allows
the plug to fit into the power outlet in only one way. If
unable to insert the plug fully into the outlet, try reversing
the plug. If the plug still fails to fit, contact an electrician to
arrange replacement of the obsolete outlet. Do not defeat the
safety purpose of the polarized plug.
Alternately, this unit may be equipped with a 3-wire ground-
ing plug (a plug with a third pin, for grounding). This safety
feature allows the plug to fit into a grounding power outlet
only. If unable to insert the plug into the outlet, contact an
electrician to arrange replacement of the obsolete outlet. Do
not defeat the safety purpose of the grounding plug.

13.

Lightning

- For added protection during a lightning storm,

or when this unit is left unattended and unused for long peri-
ods of time, unplug the unit from the wall outlet and discon-
nect the cable system. This will prevent damage to the unit
due to lightning and power line surges.

Important Safeguards

EN

© 2005 Bosch Security Systems

Page 2 of 36

Содержание AutoDome

Страница 1: ...AutoDome and EnviroDome Indoor Pendant In ceiling Model Installation Manual Version 5 3 Security you can rely on EN ...

Страница 2: ... to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from battery power refer to the operating instructions For units intended to operate wit...

Страница 3: ... from touching power lines or circuits as this contact might be fatal U S A models only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack Mount Product 1 Ventilation This unit should not be placed in a built in installation or rack unless proper ventila tion is provided or the manufacturer s instruc tions have been adhered to The equipment must not e...

Страница 4: ... être réalisée par du per sonnel qualifié conformément au code national d électricité améri cain NEC ou au code d électricité local en vigueur Coupure de l alimentation Qu ils soient pourvus ou non d un com mutateur ON OFF tous les appareils reçoivent de l énergie une fois le cordon branché sur la source d alimentation Toutefois l appareil ne fonctionne réellement que lorsque le commutateur est ré...

Страница 5: ...lek trische schokken kan veroorzaken De gebruiker dient de bedienings en onderhoudsvoorschriften te raadplegen in de documentatie die werd meegeleverd met het apparaat Sicurezza Attenzione l installazione deve essere effettuata esclusivamente da personale tecnico qualificato in conformità con il National Electrical Code o con le normative locali vigenti Scollegamento dell alimentazione Le unità do...

Страница 6: ...YCH ELEMENTÓW KTÓRE MOGÑ BYå NAPRAWIANE SAMODZIELNIE PRZEZ U YTKOWNIKA SERWIS NALE Y ZLECAå WYKWALI FIKOWANYM PRACOWNIKOM OBS UGI Ten symbol wskazuje na obecnoÊç nieizolowanego niebez piecznego napi cia we wn trzu urzàdzenia Napi cie to grozi pora eniem U ytkownik powinien zapoznaç si z instrukcjami obs ugi i konserwacji serwisu zamieszczonymi w dokumentacji Od àczanie zasilania Niezale nie od wyp...

Страница 7: ...SER COMMANDS Unlocked Commands 39 NOTE Before beginning installation please remove the USER MANUAL in the back of this booklet SECTION 1 EnviroDome and Indoor Pendant Installation Instructions Camera Addressing 1 1 To use FastAddress skip to STEP 1F Otherwise to manually set the switch address position the dome on the star shaped foam with the bubble side down Photo 1A Position dome 1 2 Remove the...

Страница 8: ... the National Electrical Code or applicable local codes Refer to the appropriate installation section The AutoDome can be mounted to a wall mast pole roof pipe or a corner mount once the appropriate mount has been installed Each mount includes its own mounting instructions Mounts must be properly and securely mounted to a supporting structure capable of sustaining the unit weight Use care when sel...

Страница 9: ...t power supply must be used b Be sure to use an adequate gauge of 24 VAC wiring for the distance run See APPENDIX A Power Wiring Guide for proper wiring instructions and recommended wire run lengths c Wire the 9 pin CONTROL connector located on the top of the unit as in STEP 1G d If the Alarm Inputs or Relay Output are being used connect the appropriate wires to the 8 pin Alarm connector Figure 1D...

Страница 10: ...oto 1G Align notches 1 10 Tighten the two screws on the top of the pendant arm until snug Photo 1H Tighten screws Some models require a slotted screw instead of an Allen screw Apply power to the AutoDome 1 11 If using the FastAddress feature see SECTION 3 for additional information Congratulations You ve installed the AutoDome Photo 1I Installed AutoDome Section 1 ALIGN NOTCHES ROTATE ...

Страница 11: ...ress skip to STEP 2C Otherwise set the address switch as shown Setting address selector to 0000 causes the AutoDome to respond to ALL messages regardless of address NOT RECOMMENDED otherwise the unit only responds to commands issued for that address If using RS 232 RS 485 Communications The unit is shipped with the RS 232 RS 485 Baud Rate set to 9600 This rate can be changed via the COMMUNICATIONS...

Страница 12: ...ustrate red markers Photo 2E Align red markers 2 6 While grasping the unit by the dome window insert the camera module completely into the backbox Photo 2F Insert camera module 2 7 While pressing up twist the dome window locking ring clockwise approximately 1 4 turn The camera will initialize ten seconds after it is properly installed Photo 2G Lock dome into place 2 8 An optional tamper clip is pr...

Страница 13: ... have not already been configured using FastAddress will respond to this command Additionally if the address of a previously configured dome matches the camera number at the keyboard that dome will respond to the command as well ON 998 ENTER All domes respond to this command regardless of FastAddress status NOTE In systems with multiple monitors other domes may also enter the FastAddress mode As c...

Страница 14: ...Dome has password protection capability for Advanced Menu access and other locked commands To set a password after entering OFF 90 ENTER enter SET 802 ENTER and follow the on screen instructions to set or change the password Passwords are four 4 digits in length and are selected via the joystick The AutoDome s default password of 0000 four zeros allows OFF 90 ENTER to directly unlock the Advanced ...

Страница 15: ...y Mask or edits an existing mask A 1x1 block is drawn in the center of the screen as shown in FIGURE 5B FOCUS deletes the selected mask and removes the signifying that the mask is now unused IRIS moves the AutoDome so that the highlighted mask is centered on the screen IRIS exits the menu TO CREATE A MASK 1 First use the joystick to maneuver to the area to be masked then zoom in so that this area ...

Страница 16: ... the joystick to move down to the Communication Setup menu and press FOCUS on the controller key board Figure 6B Communication Setup 4 Press and release FOCUS until the desired baud rate appears Then press IRIS to SAVE and EXIT 5 A countdown message will appear to confirm the baud rate change If the baud rate of the controller is changed within 60 seconds and the joystick is moved in any direc tio...

Страница 17: ...r but will not move from the current position see PHOTO 7A Photo 7A Alarm active The OSD may be turned OFF and then the camera will move to the shot but will not flash the word ALARM To acknowledge an ALARM and turn off the flashing display use the auxiliary command OFF 65 ENTER on a Bosch controller keyboard The ALARM message will be removed from the monitor but if the contact closure is still ac...

Страница 18: ...er keyboard use the sequence of ON 65 ENTER Use OFF 65 ENTER to deactivate it The function of OFF 65 ENTER is different when the trigger for the relay output is an alarm input When the alarm input is activated the relay output will also be activated immediately When the alarm is acknowledged by OFF 65 ENTER the first time the relay output will NOT deactivate It will remain on for the period select...

Страница 19: ...well The AutoTracker itself also reacts to the Inactivity setting when the AutoTracker is on and a user takes manual control of the camera AutoTracker turns off AutoTracker will remain off unless Inactivity is turned on in which case AutoTracker will turn itself back on after the Inactivity time period expires Programming AutoTrack is simple It should be completely wired to the dome before the dom...

Страница 20: ...ve 32 are repeated in multiples of 32 1 33 65 97 are the same Pelco D address above 254 are repeated in multiples of 254 1 255 509 763 are the same 9 5 Software AutoDome firmware 5 31 or higher must be installed for Pelco pro tocol mode to operate Procedures for uploading a new AutoDome firmware must be followed to successfully install an upgrade Only a Bosch VP CFGSFT firmware upload tool sold se...

Страница 21: ...n a 95 PRESET command is sent from a Pelco control device the AutoDome displays the main Setup Menu Following are the menu items and a brief description Bosch Menu Locked Accesses the full AutoDome con figuration menu and all AutoDome settings Command Lock Locked Allows Disallows ON OFF locked commands to be accessed Edit Password Locked Sets or displays password See Auto Dome Security SECTION 4 f...

Страница 22: ... functions as described in Section 9 6 Commands While the SET button is deactivated the PRESET button is used to issue the Go to Preset command This command is used to move the AutoDome to a previously defined preset position This command is also used to activate special preset functions as described in Section 9 6 Commands CM6700 Matrix Switch Presets The AutoDome must be connected to the RS 422 ...

Страница 23: ...tection clean the dome with clean com pressed air from a spray can and microwave safe paper towels then reseat the dome In instances of high humidity the EnviroDome may require a replacement desiccant bag To order contact Bosch and specify part number 303 3804 003 Service Centers U S A Phone 800 366 2283 or 408 956 3895 fax 800 366 1329 or 408 956 3896 e mail NationalServiceCenter ca slr com Canad...

Страница 24: ...ands OFF 90 ENTER may require password NOTE Commands automatically lock 30 min after being unlocked COLORS ARE NOT CORRECT 1 Try resetting factory defaults ON 40 ENTER 2 Position camera so the entire view is white white wall 3 Enter the White Balance menu ON 30 ENTER Move the joystick until one push W G is selected Wait 10 sec Press IRIS to return 4 If this does not work restore factory defaults S...

Страница 25: ...eck the RS 232 wiring to verify that RXD TXD and GROUND are all properly connected The maximum distance between the AutoTracker and AutoDome is 50 ft The AutoTrack option communicates at the default baud rate of 19 200 but if an E5 error occurs confirm that the baud rate in the Communication Setup menu is 19 200 MISSING SOME MENU SELECTIONS Menu selections specific to the AutoTrack appear only if ...

Страница 26: ... Set 110 Enter SET recalibrates camera and returns it to home position Position Restore Defaults On 40 Enter Restores Factory Defaults Left Limit Set 101 Enter Sets the current position as the left limit of Auto Pan Default is 0 degrees Right Limit Set 102 Enter Sets the current position as the right limit of Auto Pan Default is 359 9 degrees Inactivity On Off 9 Enter Selects the mode that the dom...

Страница 27: ...ite object i e a white wall or paper before activating Gain Control Electronically brightens darker scenes which may cause graininess in low light scenes The Factory Default setting is AUTO Choices Off Camera uses only the IRIS to adjust to low light Auto Camera adds electronic gain based on lighting conditions Max Gain Level Adjusts the maximum gain level that Gain control will adjust to when set...

Страница 28: ...Focus is always active even while moving Manual Auto Focus is inactive manual focus must be used Spot Auto Focus activates after the camera stops movement Once focused Auto Focus is inactive until the camera is moved again Auto Iris AutoDome automatically adjusts to varying light conditions The Factory Default setting is CONSTANT Choices Constant Auto Iris is constantly active Manual Iris must be ...

Страница 29: ...mera stops tilting when looking straight down Restore Defaults Use this to restore ALL choices for this submenu ONLY back to the Factory Defaults Choices Yes No NOTE The following two 2 PTZ SETUP options refer to AutoTrack models only and will not appear on the screen otherwise AutoTrack Comms Enables Disables the AutoTracker completely including all communications Choices On enable Off disable Ca...

Страница 30: ...d Default is YES Choices Yes No Transmit Controls whether an alarm message will be transmitted via RS 232 RS 485 Default is NO Choices Yes No Track Controls whether AutoTrack should be activated when an alarm occurs Displayed on AutoTrack models ONLY Choices Yes No AutoTrack Relay Output Contains a submenu of choices that control how the relay output will function Period Controls the time period t...

Страница 31: ...Sliding Scale 359 default 0 0 Sliding Scale 1 10 000 sec Auto Slow Shutter 1 sec NIGHT MODE NIGHT MODE THRESHOLD NIGHT MODE COLOR On Off Auto Sliding Scale 10 55 On Off On Off Factory Default SHUTTER Day Night Settings For Day Night Models Only RESTORE DEFAULTS Yes No LENS SETUP AUTO FOCUS AUTO IRIS IRIS SPEED MAX ZOOM SPEED DIGITAL ZOOM FOCUS SPEED Constant Manual Sliding Scale 1 normal 8 fast de...

Страница 32: ... SPEED Sliding Scale 1 sec 60 sec default 30 sec Sliding Scale 1 slow 15 fast default 4 3 6 m 12 ft adjustable from 2 4 to 30 7 m 8 to 100 ft Off Scene 1 Prev Aux RESTORE DEFAULTS Yes No COMMUNICATION SETUP BAUD RATE BILINX 9600 19200 38400 57600 Factory Default AutoTrack uses 19 200 Baud RESTORE DEFAULTS Yes No On Off DISPLAY SETUP DISPLAY ADJUST TITLE OSD SECTOR BLANKING On Off Changes the chara...

Страница 33: ...ally Closed Go to Shot OSD Transmit Track 0 to 99 Default Input Number Yes No No Yes No Yes RESTORE DEFAULTS Yes No RELAY OUTPUT Period Follow Input Latched Sliding Scale 1 sec to 10 min Triggered by Input 1 Input 2 Input 3 Input4 No Yes Alarm Status Displays the status of the four Alarm Inputs and the Relay Output AutoTrack Output Period Follow Input Latched Sliding Scale 1 sec to 10 min LANGUAGE...

Страница 34: ...OWER EnviroDome Transformer Output 24 VAC 50 VA Add Wire Jumper Dome Connector Dome Connector Dome Connector Transformer Output 24 VAC 30 VA Transformer Output 24 VAC 20 VA Transformer Output 24 VAC 30 VA Transformer Output 24 VAC 20 VA AWG Max Distance ft m 18 90 ft 27 43 16 140 ft 42 67 14 225 ft 68 58 C GND RXD TXD GND H C C GND RXD TXD GND H 24 VAC 24 VAC C C GND RXD TXD GND H Neutral Hot Hot ...

Страница 35: ...5 Bosch Security Systems Page 35 of 40 APPENDIX B Gasket Installation to meet IP66 NEMA 4X Dust tight and Powerful Jetting Appendix B Install Gasket with Lip on Top Plate Holds Gasket Securely Insert 4 Screws ...

Страница 36: ...EN 2005 Bosch Security Systems Page 36 of 40 AutoDome and EnviroDome Indoor Pendant In ceiling Model User Manual Version 5 3 Security you can rely on EN NOTE Remove this User Manual and supply to user ...

Страница 37: ...The name can be up to 16 characters long This Preset can later be viewed using the SHOT ENTER command where is 1 99 Figure 2 Naming a scene Preset Preset Tour Once Presets are stored the AutoDome can cycle through all Presets or selected Presets This is called a Preset tour To include or remove presets on a tour type SET 900 ENTER This displays the current Presets and indicates if they are on the ...

Страница 38: ...s all camera activities until the recording is ended by OFF 100 ENTER Once A has been recorded B is available via the ON OFF 101 ENTER command Playback can be continuous ON 50 ENTER for A ON 52 ENTER for B or one shot ON 51 ENTER for A ON 53 ENTER for B Figure 5 Recording Changing AutoPan and AutoScan speeds The AutoPan and AutoScan speeds see FIGURE 6 can be adjusted via ON 14 ENTER Use the joyst...

Страница 39: ...n activated and the ALARM message is being displayed it may be cleared by using Relay Output OFF 65 ENTER once When OFF 65 ENTER is pressed again the relay output will be deactivated ON 65 ENTER will activate the relay output regardless of alarm conditions Record A ON OFF 100 ENTER Records A camera and PTZ controls that can be played back Once the sequence is recorded you must exit record to play ...

Страница 40: ...x 1 585 223 9180 E mail security sales us bosch com www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands E mail ema securitysystems bosch com http www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Singapore Phone 65 319 3488 Fax 65 319 3499 E mail sg securitysystems bosch com ht...

Отзывы: