Interfaces
Alarm Inputs
Alarm input
Select N.O. if the alarm is to be triggered when the contact closes. Select N.C. if the alarm is
to be triggered when the contact opens.
Name
You can enter a name for each alarm input. If the Live functions are configured accordingly,
this name is displayed below the icon for the alarm input. You can also use the name in the
Forensic Search program function as a filter option for quick search in recordings. Enter a
unique and clear name here.
!
Caution!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal management.
Alarm Outputs
Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s.
Output name
Enter a name for the alarm output.
Output name / Toggle
Click the button to test the relay / output connection.