ALARM SETUP
NUMBER
ATIME
SAVE
BACK
- SET/CLEAR
1.
Select the appropriate alarm number.
2.
Select the option "In" to select the alarm input type.
3.
Select the appropriate value: N.O. (Normally Open) or N.C.
(Normally Closed).
4.
Select the option "Out" to select the alarm output.
5.
Select the appropriate value: ON or OFF.
6.
Select the option "Priority."
7.
Select the appropriate priority from 1-4.
8.
Select the option "Action."
9.
Select the appropriate action: Off, Preset, Pattern, Scan, or
Tour.
10. Select the option "Number."
11. Select the number of the action (Preset, Pattern, Scan, or
Tour).
12. Select the option "ATime" to set the alarm time for the
action.
13. Set the desired dwell time:
–
Time Out (3-60seconds). This is activated during a
selected dwell time when an alarm is triggered.
–
Momentary (On): When an alarm is triggered, the
camera will maintain alarm activation continuously,
until it is stopped manually (96+preset in Pelco
protocol; [Off]+[65]+[Enter] in Bosch protocol).
14. Save the settings.
Note: Select the option "Clear" to delete the alarm.
AUTDOME 4000 Mini
PTZ Dome
On-Screen Display (OSD) Menu | en
75
Bosch Security Systems, Inc.
2013.4 | |
Содержание AUTODOME 4000 mini
Страница 1: ...AUTDOME 4000 Mini PTZ Dome VEZ 400 Series en Operations Manual ...
Страница 2: ......
Страница 89: ......