Access Modular Controller 2
Installing | en
23
Bosch Security Systems B.V.
Installation manual
2022-03 | V03 |
Figure 4.11:
RS-485 host interface
4.9.1
RS-485 Two Wire Connection
Figure 4.12:
Setting of the jumpers for RS-485 two wire connections
4.9.2
RS-485 Four Wire Connection
Figure 4.13:
Settings for RS-485 four wire connection
Select the RS-485 address of the AMC2 controller using the DIP switch.
i
Notice!
If a four-wire connection is used the interface must be set up as a crosslink.
4.9.3
DIP switch selector
DIP switches are used to configure the host settings.
The first four DIP switches for address selection, define the RS-485 address of the AMC2 in an
RS-485 bus system.
Switch 5
selects one of the two different protocols, SDEB and BPA (according to DIN6619).
Switch 6
sets the connection to the host system to either RS-485 or the Project-specific
interface (PI).