Access Modular Controller 2
UL requirements | en
35
Bosch Security Systems B.V.
Installation manual
2022-03 | V03 |
6
UL requirements
Before installing the product in an UL system, read and follow the UL requirements described
below.
Depending on the Host Management, the system consists of:
The Access Professional Edition (APE) 3.4 or 3.5 or Building Integration System (BIS) - Access
Engine (ACE) 4.5, or AMS 2.0 as the Host Management System. This is an Access Control (UL
294 ALVY) system. It consists of the following devices - all listed to UL 294:
–
The maximum number of AMC2 controllers varies depending on the type of license
(AMC2-4R4CF, downloader version 00.49 or higher, program version 6x.xx).
–
Every controller can be extended with up to three AMC2-8IOE, AMC2-16IOE or AMC2-16IE
in any combination.
–
The enclosures AMC2-UL01 (for one device) or AMC2-UL02 (for two devices).
–
For every enclosure, a power supply Bosch APS-PSU-60 is necessary, and must be located
in the same room as the connected AMC2 device. Recommended maximum distance
between power supply unit and AMC2 is 3 m (9.84 ft).
i
Notice!
The use of the burglar alarm, panic hardware, and elevator control have not been evaluated
by UL.
For UL compliance, use only UL Listed OSDP format readers.
The following Bosch model card readers were evaluated by UL for compatibility with above-
mentioned Bosch Access Host Management System:
–
LECTUS secure 1000 RO
–
LECTUS secure 2000 RO
–
LECTUS secure 4000 RO
–
LECTUS secure 5000 RO.
6.1
System requirements
6.1.1
Computer
Host system
For detailed information about the needed Operating system and Hardware, please refer to
the corresponding installation manual of the used Management system.
i
Notice!
Computers used for UL installations must be UL listed by the Information Technology
Equipment Group (ITE).
6.2
UL 294 level descriptions
The following UL 294 levels apply:
–
ACCESS CONTROL DESTRUCTIVE ATTACK LEVEL I - An access control product intended
for, but not limited to, a controlled area that is not required to meet the destructive
Attack Test.
–
ACCESS CONTROL LINE SECURITY LEVEL I - An access control product with no
communication line security.
–
ACCESS CONTROL ENDURANCE LEVEL IV - An access control product shall operate as
intended at rated voltage and current for 100,000 cycles of intended operation.