![Bosch 7 735 500 7848 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/bosch/7-735-500-7848/7-735-500-7848_installation-and-maintenance-instructions-for-contractors_52766025.webp)
About the product
W 120-5 O – 6 720 819 306 (2018/10)
25
2.4
Specifications
2.5
Product data for energy consumption
The following product data satisfy the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013
supplementing Directive 2010/30/EU.
Unit
W 120-5 O
A
W 120-5 O
C
General Information
Dimensions
Tilt height
mm
1135
1070
Minimum room height for anode replacement
mm
1480
1420
Connections
Inner diameter, test point, cylinder temperature sensor
mm
10
10
Dry weight (excluding packaging)
kg
72
67
Total weight when filled
kg
192
187
Cylinder capacity
Useful capacity (overall)
l
115
115
Usable DHW volume
1)
with DHW outlet temperature
2)
:
1) Without recharging; set cylinder temperature 60 °C
2) Mixed water at draw-off point (at 10 °C cold water temperature)
45 °C
l
163
163
40 °C
l
190
190
Standby heat loss according to DIN EN 12897
3)
3) Distribution losses outside the DHW cylinder are not taken into account.
kWh/24 h
0.8
1.25
Maximum flow rate, cold water inlet
l/min
12
12
Maximum DHW temperature
°C
95
95
Max. operating pressure, potable water
bar
(positive)
10
10
Maximum DHW test pressure
bar
(positive)
10
10
Heat exchanger
Content
l
6.8
4.1
Surface area
m
2
1
0.6
Performance factor N
L
according to DIN 4708
4)
4) The performance factor N
L
=1 according to DIN 4708 for 3.5 persons, standard bath tub and kitchen sink.
Temperatures: cylinder 60 °C, outlet 45 °C and cold water 10 °C.
Measured at max. heat output. If the heat output is reduced, N
L
becomes smaller.
NL
1.2
1.2
Continuous output (at 80 °C flow temperature, 45 °C DHW outlet
temperature and 10 °C cold water temperature)
kW
l/min
34
13.9
20
8.2
Heat-up time at rated output
min
16
27
Maximum heat input
5)
5) In the case of heat sources with a higher heat output, limit to the stated value.
kW
34
20
Maximum heating water temperature
°C
160
160
Max. heating water operating pressure
bar
(positive)
16
16
Pressure drop diagram
Table 4 Dimensions and specifications (
Fig. 1, page 44 and Fig. 3, page 45)
Article number
Product type
Cylinder volume (V) Heat retention loss (S)
DHW heating energy efficiency class
8 732 910 201
W 120-5 O1
115.0 l
35.2 W
A
7 735 500 7848
718 543 216
W 120-5 O
ST120-5 Z
WST 120-5 O
115.0 l
52.0 W
B
Table 5 Product data for energy consumption