• For dimensions, see the sales catalog TS 2plus, 3 842 531 138.
• Maximum load/section load:
– BS 2/C-100 belt section:
max. 100 kg / 1.0 kg/cm of support surface length
– BS 2/C-250 belt section:
max. 250 kg / 1.0 kg/cm of support surface length
– BS 2/C-H belt section:
max. 400 kg / 2.0 kg/cm of support surface length
– BS 2/R-300 belt section:
max. 300 kg / 1.5 kg/cm of support surface length
– BS 4/R-300 belt section:
max. 300 kg / 1.5 kg/cm of support surface length
– BS 2/R-700 belt section:
max. 700 kg / 1.5 kg/cm of support surface length
– BS 4/R-700 belt section:
max. 700 kg / 1.5 kg/cm of support surface length
– BS 2/R-H belt section:
max. 1200 kg / 2.0 kg/cm of support surface length
– BS 2/R-V-1200 belt section: max. 1200 kg / 1.5 kg/cm of support surface length
• Noise emissions: < 70 dB (A)
16.1 Ambient conditions
• The transfer systems have been designed for stationary use in a location
that is protected from the elements.
• Operating
temperature
+5°C to +40°C
–5°C to +60°C with 20% reduced load
• Storage temperature
–25°C to +70°C
• Relative humidity
5% to 85%
• Air pressure
> 84 kPa, appropriate height < 1400 m above sea level
• Permissible fl oor load: 1000 kg/m
2
• The load values of the electrical drives are reduced by 15%
when the system is set up in a location with an altitude > 1400 m.
• Avoid molds, fungi, rodents, and other vermin.
• Do not install or operate near industrial systems with chemical emissions.
• Do not install or operate near sandy or dusty sources.
• Do not install or operate in areas that are regularly jarred by high forces
caused by e.g. presses or heavy machinery.
• Resistant to many common media used in production such as water,
mineral oil, grease, and detergents. Contact your Rexroth representative
if you have any doubts about resistance to specifi c chemicals, such as
test oil, doped oils, aggressive detergents, solvents, or brake fl uid.
• Avoid long-term contact with acidic or basic reacting materials.
EN