-11-
When no button is pressed on the tool for approx. 20 minutes
and when no laser beam reaches the reception area
5
for 20 min-
utes, the tool automatically switches off in order to save battery
power.
Selecting the Setting of the Center Indicator
With button
2
, you can specify with which accuracy the position
of the laser beam is indicated on the reception area:
– “Fine” adjustment (indication
f
on the display),
– “Coarse” adjustment (indication
e
on the display).
Whenever switching on the tool, the accuracy level “Fine” is set.
Direction Indicators
The position of the laser beam on the reception area
5
is indi-
cated:
– via the direction indicators “move downward”
b
, “move up-
ward”
d
or the center indicator
c
on the display
6
on the front
of the measuring tool,
– via the LEDs “move downward”
10
, “move upward”
12
or the
center-indication LED
9
on the back of the tool,
– optionally via the audio signal (see “Audio Signal for Indication
of the Laser Beam”).
Tool too low:
When the laser beam runs through the top half of
the reception area
5
, the direction indicator
d
on the display and
the corresponding direction LED
12
light up. When the audio
signal is switched on, a high frequency signal sounds. Move the
tool upward in the direction of the arrow.
Tool too high:
When the laser beam runs through the bottom half
of the reception area
5
, the direction indicator
b
on the display
and the corresponding direction LED
10
light up. When the audio
signal is switched on, a low frequency signal sounds. Move the
tool downward in the direction of the arrow.
Tool in center position:
When the laser beam runs through the
reception area
5
at the center mark
11
, the center indicator
c
on
the display and the corresponding center-indication LED
9
light
up. When the audio signal is switched on, a continuous signal
sounds.
www.
GlobalTestSupply
.com
Find Quality Products Online at: