background image

16

 | English 

1 609 92A 32T | (22.6.16)

Bosch Power Tools

English

Safety Notes

All instructions must be read and observed 
in order to work safely with the measuring 
tool. The integrated protections in the 
measuring tool may be compromised if the 
measuring tool is not used in accordance 

with the instructions provided. Never make warning signs 
on the measuring tool unrecognisable. STORE THESE IN-
STRUCTIONS IN A SAFE PLACE AND INCLUDE THEM WITH 
THE MEASURING TOOL WHEN GIVING IT TO A THIRD PAR-
TY.

Caution – The use of other operating or adjusting 
equipment or the application of other processing meth-
ods than those mentioned here can lead to dangerous 
radiation exposure. 

The measuring tool is provided with a warning label 
(marked with number 12 in the representation of the 
measuring tool on the graphics page).

If the text of the warning label is not in your national 
language, stick the provided warning label in your na-
tional language over it before operating for the first 
time.

Do not direct the laser beam at persons 
or animals and do not stare into the di-
rect or reflected laser beam yourself, not 
even from a distance. 

You could blind 

somebody, cause accidents or damage 
your eyes.

If laser radiation strikes your eye, you must deliberate-
ly close your eyes and immediately turn your head 
away from the beam.

Do not make any modifications to the laser equipment.

Do not use the laser viewing glasses as safety goggles. 

The laser viewing glasses are used for improved visualisa-
tion of the laser beam, but they do not protect against laser 
radiation.

Do not use the laser viewing glasses as sun glasses or in 
traffic. 

The laser viewing glasses do not afford complete 

UV protection and reduce colour perception.

Have the measuring tool repaired only through quali-
fied specialists using original spare parts. 

This ensures 

that the safety of the measuring tool is maintained.

Do not allow children to use the laser measuring tool 
without supervision. 

They could unintentionally blind 

other persons or themselves.

Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids, 
gases or dusts. 

Sparks can be created in the measuring 

tool which may ignite the dust or fumes.

Keep the measuring tool and the rotating 
mount 13 away from cardiac pacemakers. 

The magnets inside the measuring tool and the 
rotating mount generate a field that can impair 
the function of cardiac pacemakers.

Keep the measuring tool and the rotating mount 13 
away from magnetic data media and magnetically sen-
sitive equipment. 

The effect of the magnets inside the 

measuring tool and the rotating mount can lead to irrevers-
ible data loss.

Product Description and Specifica-
tions

Please unfold the fold-out page with the representation of the 
measuring tool and leave it unfolded while reading the operat-
ing instructions.

Intended Use

The measuring tool is intended for determining and checking 
horizontal and vertical lines as well as plumb points.

Product Features

The numbering of the product features shown refers to the il-
lustration of the measuring tool on the graphic page.

1

Exit opening for laser beam

2

On/Off switch

3

Battery capacity indicator

4

Working without automatic levelling indicator

5

Button for “laser point” operating mode

6

Button for “laser line” operating mode

7

Battery lid

8

Guide groove

9

Tripod mount 1/4"

10

Tripod mount 5/8"

11

Serial number

12

Laser warning label

13

Rotating mount(RM 1)

14

Guide rail

15

Fastening slot

16

Magnets

17

Ceiling clip*

18

Universal holder (BM 1)*

19

Protective pouch*

20

Case*

21

Inlay*

22

Laser target plate*

23

Construction tripod (BT 150)*

GCL 2-15

GCL 2-15 G

OBJ_BUCH-2637-002.book  Page 16  Wednesday, June 22, 2016  4:13 PM

Содержание GCL 2-15

Страница 1: ...rough quali fied specialists using original spare parts This ensures that the safety of the measuring tool is maintained Do not allow children to use the laser measuring tool without supervision They could unintentionally blind other persons or themselves Donotoperatethemeasuringtoolinexplosiveenviron ments such as in the presence of flammable liquids gases or dusts Sparks can be created in the me...

Страница 2: ...er points 0 3 mm m 0 7 mm m 0 3 mm m 0 7 mm m Self levelling range typically 4 4 Levelling duration typically 4 s 4 s Operating temperature 10 C 50 C 10 C 50 C Storage temperature 20 C 70 C 20 C 70 C Relative air humidity max 90 90 Laser class 2 2 Laser type Laser point Laser line 630 650 nm 1 mW 630 650 nm 1 mW 500 540 nm 1 mW 630 650 nm 1 mW Colour of laser beam red green C6 1 1 Divergence Laser...

Страница 3: ...o position for working with automatic levelling As soon as it is switched on themeasuringtoolemitslaser lines from the exit openings 1 Toswitchoffthemeasuringtool slidetheOn Offswitch2 to position The pendulum unit is locked when the tool is switched off When exceeding the maximum permitted operating tempera ture of 50 C the measuring tool switches off to protect the laser diode After cooling down...

Страница 4: ... levelling Figure On Offswitch2inposition green B1 Cross line operation Press button for laser line operating mode 6 once green C1 Press button for laser line operating mode 6 twice green D1 Press button for laser line operating mode 6 three times green E1 Press button for laser line operating mode 6 four times green B1 Cross line operation Point operation can be activated or deactivated regardles...

Страница 5: ...uences on Accuracy The ambient temperature has the greatest influence Espe cially temperature differences occurring from the ground up ward can divert the laser beam In addition to external influences device specific influences e g falls or heavy impacts can also lead to deviations For this reason check the levelling accuracy each time before be ginning work First checkboththeheightaswellastheleve...

Страница 6: ...ght of the measuring tool using a tripod or by underlaying if required in such a manner that the centre of the laser line is projected exactly against the previously marked point II on wall B Mark the centre of the laser line as point III vertically above or below point I on the wall A The difference d of both marked points I and III on wall A indicates the actual deviation of the measuring tool f...

Страница 7: ...viation of the measuring tool to the plumb line The maximum permitted deviation dmax can be calculated as follows dmax double the distance between floor and ceiling x 0 7 mm m Example If the distance from the floor to the ceiling is 5 m the maximum deviation is dmax 2 x 5 m x 0 7 mm m 7 mm The marks must there fore be maximum 7 mm apart Working Advice For marking always use only the centre of the ...

Страница 8: ...ater Park North Orbital Road Denham Uxbridge UB 9 5HJ At www bosch pt co uk you can order spare parts or arrange the collection of a product in need of servicing or repair Tel Service 0344 7360109 E Mail boschservicecentre bosch com Ireland Origo Ltd Unit 23 Magna Drive Magna Business Park City West Dublin 24 Tel Service 01 4666700 Fax 01 4666888 Australia New Zealand and Pacific Islands Robert Bo...