background image

 English | 

21

Bosch Power Tools

1 609 92A 32T | (22.6.16)

– Without changing the height, turn around the measuring 

tool by 180°. Direct it against the wall A in such a manner 
that the vertical laser line runs through the already marked 
point

I

. Allow the measuring tool to level in and mark the 

cross point of the laser lines on the wall A (point

III

).

– The  difference 

d

 of both marked points

I

 and 

III

 on wall A 

indicates the actual height deviation of the measuring tool.

The maximum permitted deviation d

max

 can be calculated as 

follows:
d

max

= double the distance between the walls x 0.3 mm/m

Example: If the distance between the walls is 5 m, the maxi-
mum deviation is
d

max

= 2 x 5 m x 0.3 mm/m = 3 mm. The marks must there-

fore be maximum 3 mm apart.

Checking the Levelling Accuracy of the Horizontal Line

For the check, a free surface of approx. 5 x 5 metres is re-
quired.

– Set up the measuring tool on a firm, level surface between 

both walls A and B. Allow the measuring tool to level in 
while in horizontal operation.

– At a distance of 2.5 metres from the measuring tool, mark 

the centre of the laser line (point

I

 on wall A and point

II

 on 

wall B) on both walls.

– Set up the measuring tool 5 metres away turned by 180° 

and allow it to level in. 

– Align the height of the measuring tool (using a tripod or by 

underlaying, if required) in such a manner that the centre 
of the laser line is projected exactly against the previously 
marked point 

II

 on wall B.

– Mark the centre of the laser line as point 

III

 (vertically 

above or below point 

I

) on the wall A.

– The difference 

d

 of both marked points 

I

 and 

III

 on wall A 

indicates the actual deviation of the measuring tool from 
the level plane.

The maximum permitted deviation d

max

 can be calculated as 

follows:
d

max

= double the distance between the walls x 0.3 mm/m

Example: If the distance between the walls is 5 m, the maxi-
mum deviation is
d

max

= 2 x 5 m x 0.3 mm/m = 3 mm. The marks must there-

fore be maximum 3 mm apart.

Checking the Levelling Accuracy of the Vertical Line

For this check, a door opening is required with at least 2.5 m 
of space (on a firm surface) to each side of the door.

– Position the measuring tool on a firm, level surface (not on 

a tripod) 2.5 m away from the door opening. Allow the 
measuring tool to level in while in cross-line operation 
mode, and direct the laser beams at the door opening.

– Mark the centre of the vertical laser line at the floor of the 

door opening (point

I

), at a distance of 5 m beyond the 

other side of the door opening (point

II

) and at the upper 

edge of the door opening (point

III

).

d

180°

A

B

2,5 m

5,0 m

5,

5

A

B

2,5 m

d

5,0 m

2,5 m

A

B

2,5 m

2,5 m

OBJ_BUCH-2637-002.book  Page 21  Wednesday, June 22, 2016  4:13 PM

Содержание GCL 2-15

Страница 1: ...rough quali fied specialists using original spare parts This ensures that the safety of the measuring tool is maintained Do not allow children to use the laser measuring tool without supervision They could unintentionally blind other persons or themselves Donotoperatethemeasuringtoolinexplosiveenviron ments such as in the presence of flammable liquids gases or dusts Sparks can be created in the me...

Страница 2: ...er points 0 3 mm m 0 7 mm m 0 3 mm m 0 7 mm m Self levelling range typically 4 4 Levelling duration typically 4 s 4 s Operating temperature 10 C 50 C 10 C 50 C Storage temperature 20 C 70 C 20 C 70 C Relative air humidity max 90 90 Laser class 2 2 Laser type Laser point Laser line 630 650 nm 1 mW 630 650 nm 1 mW 500 540 nm 1 mW 630 650 nm 1 mW Colour of laser beam red green C6 1 1 Divergence Laser...

Страница 3: ...o position for working with automatic levelling As soon as it is switched on themeasuringtoolemitslaser lines from the exit openings 1 Toswitchoffthemeasuringtool slidetheOn Offswitch2 to position The pendulum unit is locked when the tool is switched off When exceeding the maximum permitted operating tempera ture of 50 C the measuring tool switches off to protect the laser diode After cooling down...

Страница 4: ... levelling Figure On Offswitch2inposition green B1 Cross line operation Press button for laser line operating mode 6 once green C1 Press button for laser line operating mode 6 twice green D1 Press button for laser line operating mode 6 three times green E1 Press button for laser line operating mode 6 four times green B1 Cross line operation Point operation can be activated or deactivated regardles...

Страница 5: ...uences on Accuracy The ambient temperature has the greatest influence Espe cially temperature differences occurring from the ground up ward can divert the laser beam In addition to external influences device specific influences e g falls or heavy impacts can also lead to deviations For this reason check the levelling accuracy each time before be ginning work First checkboththeheightaswellastheleve...

Страница 6: ...ght of the measuring tool using a tripod or by underlaying if required in such a manner that the centre of the laser line is projected exactly against the previously marked point II on wall B Mark the centre of the laser line as point III vertically above or below point I on the wall A The difference d of both marked points I and III on wall A indicates the actual deviation of the measuring tool f...

Страница 7: ...viation of the measuring tool to the plumb line The maximum permitted deviation dmax can be calculated as follows dmax double the distance between floor and ceiling x 0 7 mm m Example If the distance from the floor to the ceiling is 5 m the maximum deviation is dmax 2 x 5 m x 0 7 mm m 7 mm The marks must there fore be maximum 7 mm apart Working Advice For marking always use only the centre of the ...

Страница 8: ...ater Park North Orbital Road Denham Uxbridge UB 9 5HJ At www bosch pt co uk you can order spare parts or arrange the collection of a product in need of servicing or repair Tel Service 0344 7360109 E Mail boschservicecentre bosch com Ireland Origo Ltd Unit 23 Magna Drive Magna Business Park City West Dublin 24 Tel Service 01 4666700 Fax 01 4666888 Australia New Zealand and Pacific Islands Robert Bo...

Отзывы: