Extension Cords
• Replace damaged cords immediately. Use of
damaged cords can shock, burn or electrocute.
• If an extension cord is necessary, a cord with
adequate size conductors should be used to
prevent excessive voltage drop, loss of power
or overheating. The table below shows the
correct size to use, depending on cord length
and amperage rating on the tool’s nameplate. If
in doubt, use the next heavier gauge. Always
use U.L. and CSA listed extension cords.
Ampere Rating (shown on nameplate)
0-
2.1-
3.5-
5.1-
7.1-
12.1-
2.0
3.4
5.0
7.0
12.0
16.0
25'
18
18
18
18
16
14
50'
18
18
16
16
14
12
75'
18
18
16
14
12
10
100'
18
16
14
12
10
150'
16
14
12
12 Wire Gauge
Note: The smaller the gauge number, the larger
the wire is in the cord.
Cord Length
Air flow setting:
The air flow is set steplessly with air flow
blower speed dial
3
. A lower air stage may be
required in certain cases, e.g. to avoid over-
heating the workpiece's surroundings or to
avoid displacing the workpiece if the air flow
is too strong. A higher air stage heats up the
workpiece more quickly and enables the hot air
gun to be held at a greater distance from the
workpiece.
ON/OFF switch
(Cool air stage) 8.8 CFM ª120ºF.
For cooling down a hot workpiece or for drying
paint.
(Hot air stage) 17.8 CFM ª1100ºF.
Temperature control
(thermo-electronic):
The temperature can be controlled steplessly
with the setting dial
5
and switch
6
in setting II.
If the nozzle is hot or if you wish to have both
hands free when working, you can set the tool
down in an upright position on its base.
Temperature displays:
The temperature is displayed via LED
4
. By
carefully controlling the air flow and tempera-
ture, very precise work can be performed on
temperature sensitive electrical fittings, pack-
aging, and other materials.
"SAVE THESE INSTRUCTIONS"
I
II
Double Insulated Tools
• Double Insulation
is a design concept
used in electric power tools which eliminates
the need for the three wire grounded power cord
and grounded power supply system. It is a
recognized and approved system by
Underwriter’s Laboratories, CSA and Federal
OSHA authorities.
IMPORTANT:
Servicing of a tool with
double insulation requires care and knowledge
of the system and should be performed only by
a qualified service technician. WHEN SER-
VICE IS REQUIRED USE ONLY IDENTI-
CAL REPLACEMENT PARTS.
POLARIZED PLUGS: If your tool is equipped
with a polarized plug (one blade is wider than
the other), this plug will fit in a polarized outlet
only one way. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit,
contact a qualified electrician to install the
proper outlet. To reduce the risk of electric
shock do not change the plug in any way.
Operating the Tool
O
I
II
III
I
II
1 - 15
t
herm
o-e
le
c
tr
o
n
ic
1
5
•
13
•
9
•
7
•
5
•
3
•
1
100 - 155
3
205- 250
5
270 - 300
7
370 -395
9
465-495
11
515- 545
13
565-595
15
1
°C
50
50
°F
120
210-310
400-480
520-570
700-740
870-920
960-1010
1050-1100
120
Thermo-electronic
BM 2610910610 9/01
10/4/01, 10:12 AM
6