12
Disposal
Environmental protection
Careless disposal of the IMenip2 interface
module could lead to pollution of the environ-
ment.
Therefore dispose of the device in accord-
ance with the currently applicable regulations
in your country.
You can also send the device to Bosch
Rexroth for disposal.
13
Extension and conver-
sion
Do not convert the IMenip2 interface module.
14
Troubleshooting
Malfunctions and information on errors are
displayed in the tightening system, e.g. in the
BS350.
The NS LED indicates the Ethernet status.
The MS LED indicates the interface module
status.
If you should not be able to remedy an occur-
ring defect, please contact one of the ad-
dresses that you can find under
www.boschrexroth.com or in the address di-
rectory in chapter “16 Service and sales” on
page 26.
Tab.4: NS
LED display
Meaning
Red
Double IP address or block-
ing error
Flashing red
Time-out reached in one or
more connections (CIP class
1 or 3)
Tab.5: MS
LED display
Meaning
Red
Error (exception error or blocking
error)
Flashing red
Self-acknowledged error. Used
configuration differs from stored
configuration