Device description
Transfer rates of 10 MBit/s or 100 MBit/s are
supported.
Fig. 1: IMenip2 interface module, front view
(socket)
1
NS LED (network status)
2
MS LED (module status)
3
Port 1: LINK LED (connection/activity)
4
Port 2: LINK LED (connection/activity)
Interface connection
The interface has an 8-pin RJ45 socket de-
sign.
Suitable connection plugs
Use connection plugs in accordance with
standard IEC 61158.
Display elements
The NS LED indicates the Ethernet status.
The MS LED indicates the interface module
status.
The LINK LED indicates the connection or
activity via Ethernet.
Tab.1: NS
LED display
Meaning
Off
No voltage or invalid IP address
Green
Online, one or more connections
to master established (CIP class
1 or 3), ready for operation
Flashing
green
Online, no connection to master
established
Red
Double IP address or blocking
error
Flashing red
Time-out reached in one or more
connections (CIP class 1 or 3)
Tab.2: MS
LED display
Meaning
Off
No voltage
Green
Module controlled by a scanner
during operation
Flashing
green
Not configured or scanner in idle
mode
Red
Error (exception error or blocking
error)
Flashing red
Self-acknowledged error. Used
configuration differs from stored
configuration
Tab.3: LINK
LED display
Meaning
Off
No connection, no activity
Green
Connection (100 Mbits/s) estab-
lished
Flickering
green
Activity (100 Mbits/s)
Yellow
Connection (10 Mbits/s)
established
Flickering yel-
low
Activity (10 Mbits/s)