background image

Page 

9

 of 

12

 Rev 03

 

 

 

 

REAL 49

 

 

7– Using SIRIO during incubation

 

Turn on the incubator and make it run dry without water and without eggs for at least a few hours. 

 

After two hours of no

-

load operation, insert the eggs and make it run for at least another 2

-

3 hours. 

 

After the 2

-

3 hours of incubator operation with the eggs inserted, turn on Sirio by inserting the power supply jack 

in its front socket. Next insert the feeder plug into a power outlet.

 

The display will show the desired humidity value detected, the symbol “H” means “humidity”.

 

To  set  the  desired  humidity  value,  act  on  the  buttons  (+)  and  (

-

)  located  on  the  control  panel.  By  pressing 

indifferently on one of the two keys, you enter the memory (the letter “P” appears next to the numbers), then press 
the keys on impulse until the desired value is reached, as per paragraph No. 9. Once the humidity is set, wait for this 
value to be saved (when current internal humidity re

-

appears along with the letter “H” on the display).

 

From this moment, SIRIO starts working by pumping water inside the incubator when necessary, making a rotating 
symbol appear on the display. In other moments the appliance remains in standby

 

SIRIO  is  programmed  to  inject  small  drops  of  water  little  by  little,  in  order  to  allow  the  evaporation  which 
determines the environment required relative humidity. Upon start

-

up, it will require 2 to 4 hours to reach the set 

humidity value. If the quantity of water inside the incubator is more than necessary, the time required to reach the 
set humidity value may be longer. 

 

ATTENTION: if for brief periods (even a whole day) the humidity is not correct, this does NOT result in any imbalance 
in the incubating process in progress.

 

ATTENTION:  if  during  incubation  it  were  necessary  to  carry  out  candling  or  cool  down  the  eggs  (as  with 
incubation of palmipeds), disconnect SIRIO from the power outlet  before opening the cover. This will keep the 
pump from continuing to insert water into the incubator when the humidity goes down due to opening.

 

Once the operations are completed, reconnect SIRIO to the power outlet after at least two hours.

 

Содержание SIRIO

Страница 1: ...by the manufacturer is forbidden 6 Do not use outdoors 7 The appliance can be used by children under 12 years of age and or persons with reduced physical or mental capacity or without experience or the necessary knowledge as long as supervised by an adult or after they have received instructions related to safe appliance use and understand the dangers related to it The same is true for cleaning an...

Страница 2: ... 6 3 Sensor positioning 7 7 Using SIRIO during incubation 9 8 Using SIRIO during hatching 10 9 Humidity parameters for incubation 10 10 Using SIRIO with other brand incubators 11 11 SIRIO maintenance and cleaning 11 12 Disposal 11 13 Warranty after sale service 12 Electronic format copy of this instructions manual can be downloaded from the site www borotto com or can be requested by writing to th...

Страница 3: ...mal eggs specifically hen pheasant turkey guinea fowl quail grey partridge partridge goose muscovy common wild duck peacock rock partridge pigeon Virginia quail exotic birds and birds of prey The following declaration of conformity is issued under the manufacturer s exclusive responsibility And it conforms to the following directives Directive EN 61326 1 2007 Directive EN 61010 1 2010 Directive EN...

Страница 4: ...ower supply Positive polarity at the centre of the power supply connector 3 Identification plate The equipment is fitted with an identification plate showing the equipment s identification details and the main technical specifications SIRIO automatic humidifier Year XXXX Code SIRIO Portata 0 5 l h ca Bar 0 2 Serial Number XXXX Weight Kg 0 435 Classe II Imput voltage 12 V DC MAX Power 4W Made in It...

Страница 5: ...ent with the technical and safety specifications of the equipment and for the manual refilling of water inside an incubator machine making it possible to automatically maintain the set humidity rate 5 Technical features and specifications Equipment model SIRIO SIRIO Power supply voltage 12V DC Maximum absorbed power 4 W Average daily consumption 1 Wh Feeder power supply voltage already included 10...

Страница 6: ...objects between the product and the plane for example tablecloths or covers Position SIRIO next to the incubator placing a water container nearby Any container can be used bottle canister etc as long as it is clean inside Dirty containers may result in the development of bacterial flora during incubation causing the death of the embryo Insert the suction pipe the one connected to the rubber holdin...

Страница 7: ...tone remove it with anti scaling agent before inserting the valves 6 3 Sensor positioning Insert the humidity sensor inside the incubator positioning it above the flap in the corner use a minimum amount of pressure to ensure blocking The sensor cable must remain resting on the flat side on the edge of the incubator as shown in the photo It is a special anti crushing cable therefore it will not be ...

Страница 8: ...Page 8 of 12 Rev 03 Position the humidity sensor on the opposite side of the incubator compared to the filling nozzles DO NOT PLACE THE SENSOR ABOVE THE WATER INLET TANKS REAL 12 REAL 24 ...

Страница 9: ...er H on the display From this moment SIRIO starts working by pumping water inside the incubator when necessary making a rotating symbol appear on the display In other moments the appliance remains in standby SIRIO is programmed to inject small drops of water little by little in order to allow the evaporation which determines the environment required relative humidity Upon start up it will require ...

Страница 10: ... not compromise the result In fact the first chick births since they are wet will cause a quick increase of the relative humidity level ATTENTION Do not incubate with the environment temperature below 20 C Below this value the temperature of the plastic bottom of the incubator cold does not allow the water to evaporate SIRIO then continues to pump water into the incubator unnecessarily flooding it...

Страница 11: ...ately 15 minutes recovering and disposing of the pumped aqueous solution leave the pump running dry for another 15 minutes We recommend using bleach since it destroys the bacterial flora and any residue does not damage the embryos under development DO NOT USE ANY OTHER CHEMICAL SUBSTANCES FOR CLEANING AND SANITISING SIRIO FOR ANY REASON With variable frequency depending on hardness of the water us...

Страница 12: ...ot authorised by the Manufacturer force majeure earthquakes floods fires etc Only use the appliance for the purpose it is intended for uses other than those indicated in these instructions shall be deemed as hazardous and the Manufacturer disclaims any and all liability for any damage to persons animals or property arising from failure to comply with this warning The Manufacturer shall not be deem...

Отзывы: