Page
7
of
12
Rev 03
6.2 Valve positioning
Insert the 2 valves with the pipes already connected to the incubator nozzles, making sure that they sufficiently
penetrate the bottom in order to ensure hermetic seal. Attention to their insertion direction, it should follow the
shape of the nozzle.
ATTENTION: if the filling nozzles become encrusted with limestone, remove it with anti
-
scaling agent before
inserting the valves.
6.3 Sensor positioning
Insert the humidity sensor inside the incubator, positioning it above the flap in the corner (use a minimum amount
of pressure to ensure blocking).
The sensor cable must remain resting on the flat side on the edge of the incubator as shown in the photo. It is a
special anti
-
crushing cable, therefore it will not be damaged with the machine closed.
Not perfectly closing the cover does not compromise functionality and the hatching results of the incubator in any
way.