42 |
u1 Undercounter Systems
Install & Operation Guide
GB
Trouble Shooting
Fault Diagnosis Guide 5 – Miscellaneous
Problem/ Report
Possible Cause
Suggested Action
Miscellaneous
Bleeping Noise
Waste Container full/Internal
water leak.(If fitted)
Empty Waste Container.
Check and reset Leak Detector.
No LED Control Lights
No electricity to Machine.
Check power supply and
reconnect as necessary (Also
check out other symptoms as
described separately).
Check Fuse in IEC Socket.
Replace if necessary.
Faulty Control PCB (Machine
working normally otherwise).
Replace Control PCB.
Machine shakes on Start-Up
Compressor Starting.
No action needed. This is
quite normal.
Level Surface.
Uneven Surface.
Level up machine using
adjustable feet.
Missing Fixings.
Replace missing fixings.
Tripping out Electricity supply
Machine in high humidity
environment.
Discuss possible repositioning
with customer.
Electrical circuitry faults.
Test, identify and address
accordingly. See Electrical
Diagrams.
Contact Aftersales support for
further advice.
Содержание u1
Страница 2: ...The manual is intended as a guide only Printed by Borg Overström NR9 5SP UK Copyright Borg Overström ...
Страница 4: ...4 u1 Undercounter Systems Install Operation Guide GB ...
Страница 10: ...10 u1 Undercounter Systems Install Operation Guide GB ...
Страница 20: ...20 u1 Undercounter Systems Install Operation Guide GB ...
Страница 32: ...32 u1 Undercounter Systems Install Operation Guide GB ...
Страница 36: ...36 u1 Undercounter Systems Install Operation Guide GB ...
Страница 44: ...44 u1 Undercounter Systems Install Operation Guide GB ...
Страница 62: ...62 u1 Undercounter Systems Install Operation Guide GB ...
Страница 63: ...u1 Undercounter Systems Install Operation Guide 63 GB ...