u1 Undercounter Systems
Install & Operation Guide
GB
and always allow adequate connecting
pipe length to enable the unit to
be sufficiently moved for any future
disconnection. Do not turn the water
supply on at this stage.
The maximum recommended inlet
pressure is 3.5bar.We recommend fitting
a check valve, a pressure reducing
valve and a ‘Waterblock’ device.
(These are available as part of our
optional Installation Kit). When fitting
a Waterblock device we recommend a
minimum setting of ‘2’ be used.
Pre-flush and fit the filter in an accessible
position
17
15
16