COLD
Do not open the regulator valve until the
carbonated switch has been turned on.
It will be necessary to leave the machine
for up to 1 hour for sparkling water to
develop, by absorbing the CO2.
6
CO
2
Bottle Installation
& Sparkling Water Operation
Unpack CO2 Regulator and fit elbow
fitting to spigot outlet.
Attach the regulator to the disposable
CO2 bottle, ensuring the small pressure
relief vent in the stem is facing away from
you or anyone else. Ensure the regulator
is closed. Hand tighten securely.
Stand the cylinder in a suitable place.
Flush through approximately 10 litres
of water using the sparkling button*.
Depending on the inlet water pressure,
you may have to pause approx. every
500ml to allow the carbonation tank
to refill. Check and adjust the CO2
pressure accordingly.
Connect the assembled CO2 bottle and
regulator to the CO2 inlet on the back
panel using ¼” pipe.
1
4
7
2
5
8
3
After completing the water installation,
turn on the soda power switch and the
pump will run. Allow the carbonation
tank to fill. (The carbonation pump
will run for approx. 15-20 secs). We
recommend between 3.5 - 5 bar (max).
Do not exceed 5 bar pressure.
5 Max bar
5
10
L
1
hour
Содержание u1
Страница 2: ...The manual is intended as a guide only Printed by Borg Overström NR9 5SP UK Copyright Borg Overström ...
Страница 4: ...4 u1 Undercounter Systems Install Operation Guide GB ...
Страница 10: ...10 u1 Undercounter Systems Install Operation Guide GB ...
Страница 20: ...20 u1 Undercounter Systems Install Operation Guide GB ...
Страница 32: ...32 u1 Undercounter Systems Install Operation Guide GB ...
Страница 36: ...36 u1 Undercounter Systems Install Operation Guide GB ...
Страница 44: ...44 u1 Undercounter Systems Install Operation Guide GB ...
Страница 62: ...62 u1 Undercounter Systems Install Operation Guide GB ...
Страница 63: ...u1 Undercounter Systems Install Operation Guide 63 GB ...