Basic Troubleshooting
Problem/Report
Possible Cause
Suggested Action
No Water Dispensing
Water Pressure Regulator
Contact your distributor
No Sparkling Water -
If applicable
No CO2 pressure
Check CO2 bottle, regulator and non- return
valve. Supply pressure should be 58 psi (3.5-
4bar), replace as necessary
Carbonator Tank Not Filling
Contact your distributor
Poor Quality Carbonation -
If applicable
Air in Carbonator Tank
Isolate the power supply and operate the
sparkling water tap until gas is expelled. Allow
gas to expel for 5 seconds. Switch on power
supply and allow the tank to refill
Residue in Carbonator Tank
After prolonged use, a surface film can develop
within the carbonator tank. Refer to cleaning
and sanitising instructions
Carbonator Tank is Overfilled
If pump runs continuously, contact your
distributor
Warm Drinks
Insufficient cooling air flow through the fridge
Check that the ventilation kit has been installed
correctly.
Compressor not running
Contact your distributor
PCB not operating
Fridge failure
Waste Electrical Products:
- The WEEE symbol indicates that this item contains electronic components which must be
collected and disposed of separately.
- Never dispose of electrical waste in general municipal waste. Collect and dispose of
such waste separately.
- Make use of the return and collection systems availble to you, or your local recycling
programme. Contact your local authority or place of purchase to find out what schemes
are available.
- Electrical and electronic equipment contains hazardous substances which, when diposed
of incorrectly, may leak into the ground. This can contribute to soil and water pollution
which is hazardous to human health; and endangers wildlife.
- It is essential that consumers look to re-use or recycle electrical or electronic waste to avoid
it going to landfill sites or incineration without treatment.