background image

This appliance can be used by children aged from 8 years and above and 
persons with reduced physical, sensory or mental capabilities or lack of 
experience and knowledge if they have been given supervision or instruction 
concerning use of the appliance in a safe way and understand the hazards 
involved. Children shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without supervision   

The unit should be isolated from the electricity supply before removal of any covers. Great care must be employed 
when working with high pressure carbon dioxide, and in no cases should the maximum operating pressure of 
0.4MPa (4 bar) be exceeded.

- The appliance is not suitable for installation in an area where a water jet could be used.
- The appliance has to be placed in a horizontal position

WARNING: Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
WARNING: Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.

This appliance is intended to be used in household and similar applications such as:-

 

- Staff kitchen areas in shops, offices and other working environments;

 

- Farm houses and by clients in hotels, motels and other residential type environments

 

- Bed and breakfast type environments;

 

- Catering and similar non-retail applications

A-weighted emission sound pressure level is below 70 dB(A)

 

Safety

R290 is a refrigerant-grade propane used on a wide range of commercial refrigeration 

and air conditioning units. A highly pure propane, it has a low environmental impact 

and nominal global warming potential (GWP), meaning it possesses no qualities that 

can destroy the ozone layer. R290 also is the preferred hydrocarbon alternative of the 

Environmental Protection Agency (EPA), substituting more harmful fluorocarbon refrigerants 

like R22, R134a, R404a and R502. 

Units with R290 can only be maintained and repaired by authorized technicians who are 

properly trained and certified.

Содержание C2

Страница 1: ...tents Component Feature Overview Operation Functions Controls General Safety CO2 Bottle Installation Chilled Ambient Sparkling NOTE This booklet to be left with appliance following installation User Guide C2 C3 Tap systems ...

Страница 2: ... positioning the appliance ensure the supply cord is not trapped or damaged WARNING Do not locate multiple portable socket outlets or portable power supplies at the rear of the appliance This appliance is intended to be used in household and similar applications such as Staff kitchen areas in shops offices and other working environments Farm houses and by clients in hotels motels and other residen...

Страница 3: ... Overview C2 C3 Tap Please Note Mains Installation Kit Filters are supplied as extra items according to individual ordering requirement Water Inlet Top Panel Unit Carry Handle Side Panel Front Panel CO2 Inlet Power Connection On Off Switch Sparkling versions only Contents 1 no ProCore Unit 1 no 2 0m Power Cord Set 1 no Co2 Regulator with Gauge Connection tube 1 no Ventilation Ducting Kit ProCore U...

Страница 4: ...e or decrease flow rate Lever in the upright position is fully closed Ambient Water Tap Sparkling Water Tap Chilled Water Tap Flow Restrictor Lever OPEN OPEN CLOSED Sparkling versions only Dispensing from unit Pull and hold the dispense lever towards you and release to finish dispense ...

Страница 5: ... it is liable to freeze If the unit is thought to be frozen it must not be switched on It should be allowed to thaw and must then be thoroughly inspected to ensure it is undamaged Water Mains potable water internally regulated to 0 3MPa 3 bar Minimum to maximum ambient room operating temperature 5 C 35 C CO2 Food Grade CO2 to be supplied Min mains pressure 0 05MPa 0 5 bar Electricity 5A supply Ear...

Страница 6: ...austic alkaline agent Always use responsibly and with care remembering that due to it s alkaline nature 5 sec 2Ltr 5 sec 11 12 13 14 15 16 17 18 19 1 1 0 1 1 1 1 1 2 1 1 3 1 1 4 1 1 5 1 1 6 1 1 7 1 18 1 1 9 1 20 Sanitisation Guide To be completed by a technician or service provider ...

Страница 7: ...ks Insufficient cooling air flow through the fridge Check that the ventilation kit has been installed correctly Compressor not running Contact your distributor PCB not operating Fridge failure Waste Electrical Products The WEEE symbol indicates that this item contains electronic components which must be collected and disposed of separately Never dispose of electrical waste in general municipal was...

Страница 8: ...port its weight During use this machine must remain in its upright position Adequate ventilation must be allowed for we recommend using the supplied ventilation ducting kit Keep the machine away from sunlight heat and moisture The environment where this machine is installed must be free of dust and corrosive explosive gases Copyright Borg Overström This guide is printed by Borg Overström and shall...