Fault Diagnosis: Water Leaks
Problem/Report
Possible Cause
Suggested Action
Water lying on top edge of lower
door panel and/or bottom of the
machine.
Overflowing Drip Tray waste
container.
Empty Waste Container and check
drainpipe is not blocked.
Water lying in bottom of machine.
Leak in supply inlet pipe work and/
or filter.
Locate and repair accordingly.
Leak from machine water pipes
and/or fittings.
Locate and repair accordingly.
Check pressure and fit pressure
reducing valve if needed.
Overflowing cold tank.
R
eservoir Variant: float valve not
connected or malfunctioning -
replace if necessary.
Direct Chill Variant: float valve or
internal cold tank water fittings
not connected or malfunctioning -
replace if necessary.
Water pressure too high.
Check pressure and fit pressure
reducing valve if needed.
Jammed float valve.
Check and repair float valve.
Split Float Valve washer.
Replace washer.
Overflowing cold tank (Hot Tank
exclusively sealed).
Replace hot tank.
Hot Tank thermistor probe not
working.
Check and replace probe
(Conversion Kit recommended).
Control Board not working.
Check and replace main
control board (Conversion Kit
recommended).
Condensation from tank or cold
water pipe.
Check insulation and repair/
replace accordingly.