23
2005 Boreal Geothermal Inc.
www.boreal-geothermal.com
Heating
Ground
Temp.
Heat of
Absorption
EAT
LAT
Diff
Btu's
Out
Comp
Amps
Comp
Watts
Blower
Amps
Blower
Watts
Total
Watts
COP
Suct
Disc
Pres
70
45163
70.2
109.0
38.8
59556
19.4
3640
4.2
405
4045
4.3
88
282
60
40104
70.5
105.9
35.4
53285
18.7
3489
4.1
407
3896
4.0
75
267
55
37560
70.2
104.0
33.8
51532
18.4
3393
4.4
410
3803
4.0
68
258
50
34335
70.2
102.7
32.5
48670
17.9
3296
4.4
401
3697
3.9
62
250
45
32607
69.8
100.5
30.7
45594
17.3
3178
4.4
406
3584
3.7
57
240
41
30635
69.8
99.3
29.5
43956
17.4
3129
4.4
414
3543
3.6
54
234
35
26674
69.6
96.4
26.8
38008
16.6
2963
4.6
415
3378
3.3
45
219
30
22677
69.6
95.0
25.4
35919
16.6
2877
4.5
424
3301
3.2
39
210
Ground
Temp.
EAT
LAT
Diff
Sens.
cooling
Latent
Cooling
Total
Cooling
Comp.
Amps
Comp
Watts
Blower
Amps
Blower
Watts
Total
Watts
EER
Suct
Disc
Pres
50
79.7
61.0
18.7
29000
9064
38064
12.8
2102
4.29
412
2515
15.1
68
156
60
79.9
62.2
17.7
27121
8817
35938
14.1
2483
4.09
410
2893
12.4
70
202
70
79.7
61.7
18.0
27911
7929
35840
14.8
2650
4.2
412
3062
11.7
70
219
80
80.2
62.5
17.7
26992
7277
34269
16.0
2988
4.15
409
3397
10.1
72
258
Cooling
Capacity Data *
Model ACDX-45-HAC (nominal 3.5 ton)
Comp: AV5542G Recip.
BM: HE / .33 Marathon
G-10 Blower
2-row / 6-circuit air coil
1/2” x 210 ft loops @ 41° Heating
Voltage: 230/1/60
Entering Air: 70DB / 60WB
CFM: 1550
External Static: .15” WC
1/2” x 210 ft loops @ 77° Cooling
Capacity Data *
Model ACDX-55-HAC (nominal 4 ton)
Heating
Ground
Temp.
Heat of
Absorption
EAT
LAT
Diff
Btu's
Out
Comp
Amps
Comp
Watts
Blower
Amps
Blower
Watts
Total
Watts
COP
Suct
Disc
Pres
70
60745
70
111.4
41.6
70897
23.0
4780
3.4
318
5089
4.1
84
302
60
50181
70.5
110.9
40.4
61739
20.7
4356
3.5
325
4673
3.9
72
276
55
46173
70.2
108.4
38.2
58374
19.5
4132
3.5
324
4447
3.8
65
262
50
42875
70.2
105.2
35.0
53868
18.8
3943
3.4
356
4288
3.7
60
250
45
38208
69.8
102.6
32.8
49602
18.4
3764
3.4
329
4083
3.6
54
240
40
35795
69.8
100.2
30.4
46611
17.6
3594
3.5
338
3923
3.5
50
230
35
31942
69.6
97.6
28.0
42399
16.5
3410
3.6
338
3738
3.3
44
220
30
29447
69.6
95.8
26.2
40126
15.9
3256
3.6
335
3581
3.3
41
212
Ground
Temp.
EAT
LAT
Diff
Sens.
cooling
Latent
Cooling
Total
Cooling
Comp.
Amps
Comp
Watts
Blower
Amps
Blower
Watts
Total
Watts
EER
Suct
Disc
Pres
50
80.2
52.7
27.5
38549
20002
58550
16.3
3490
3.4
341
3830
15.3
68
171
60
80.1
53.5
26.5
35828
18517
54345
17.6
3749
3.4
328
4077
13.3
70
193
70
79.9
54.4
25.4
34484
17432
51916
18.4
4013
3.5
335
4348
11.9
72
217
77
80.2
55.2
25.0
34023
17456
51479
19.8
4267
3.4
338
4605
11.2
74
240
Cooling
* - In accordance with CAN/CSA C748-M94 performance standard for ACDX geothermal heat pumps.