EN
19
Installation
www.bora.com
Q
Q
If the connection line has been damaged this must be
replaced by a special connection line. This may only
be done by an authorized member of the After Sales
Service team.
X
X
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
X
X
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
X
X
Only connect the cooktop using a permanent
connection to a power supply cable.
1
L1
L2
2
3
N
PE
220 - 240 V~
220 - 240 V~
Fig. 5.20 Connection diagram 2-phase
1
L1
2
3
N
PE
220 - 240 V~
Fig. 5.21 Connection diagram 1-phase
X
X
Check that installation has been done correctly.
X
X
Switch on the main switch/automatic circuit breaker.
X
X
Put the cooktop into operation (see the Operation
section).
X
X
Check that all the functions are working correctly.
5.6 Configuration menu
Once installation is complete, you can adjust the basic
settings for the cooktop, these can then be changed at
any time.
5.6.1 Accessing the configuration menu
X
X
Twist the control knob to the 11 o’clock position.
t
appears in the control knob display.
X
X
Press the touch surface of the control knob for a
second. The display switches to
000
.
X
X
Press the touch surface again within 3 seconds and
hold it down for 5 seconds.
Q
Q
The control knob display shows
C
, a beep sounds and
the configuration menu is available.
5.6.2 Select menu option
X
X
Turn the knob ring to select the menu option you want.
Connect the control knob to the cooktop
3
2
1
Fig. 5.19 Connection the control knob to the cooktop on the
rear
[1]
Connection the control knob for the front cooking zone
[2]
Connection the extraction system
[3]
Connection the control knob for the rear cooking zone
X
X
Connect the connection on the back of the control
knob to the connections provided at the rear of the
cooktops.
X
X
Use the connections provided to join the cooktop
extractor to the extraction system on the rear of the
cooktop.
X
X
Use the ribbon cable provided.
5.5.6 Establishing the power connection
X
X
Observe all safety and warning information
(see the Safety section).
X
X
Observe all national and regional laws and regulations
as well as the supplementary regulations of the local
utility companies.
INFO
The power connection may only be established
by certified specialists. The specialist
also assumes responsibility for the proper
installation and commissioning.
The power supply line for use (pre-assembled) must be at
least Type SiHF.
(See table Fuse protection and minimum cross-section).
Connection
Fuse protection
Minimum
cross-section
1-phase connection
1 x 25 A
2.5 mm²
2-phase connection
2 x 16 A
2.5 mm²
Tab. 5.3 Fuse protection and minimum cross-section