EN
22
Installation
www.bora.com
Preparing connection cables for external
switching devices
Use connection cables of the following types and from
the following manufacturer to connect external switching
devices.
Contact
Connection cable
Home In
H03VV-F 2x0.5mm²
Home Out
H03VVH2-F 2x0.75mm²
Tab. 6.4 Connection cable
INFO
The connection cable is only designed for
indoor use in buildings, private households,
kitchens or offices!
INFO
The overall length of the connection cable for
external switching devices must not exceed
10 m!
For reasons of electromagnetic compatibility, all
connection cables from external switching devices must
be filtered with a ferrite sleeve. This is not included in the
scope of delivery.
X
X
Use the order code UFH (universal filter sleeve) to
order the filter sleeve from your specialist supplier or
contact BORA via the website at www.bora.com.
Abb. 6.30 Wrap the connection cable around the ferrite sleeve
three times
X
X
Wrap the connection cable around the ferrite sleeve
three times to create the desired filter performance.
X
X
Ensure that the cable end protrudes at least 120 mm
from the sleeve.
X
X
Prepare the connection cable in accordance with the
prescribed stripping lengths.
The following switch contacts can be used:
Contact
Function
Connection
Home In
Cooktop extractor on/off connection
for external switch contact (contact
closed: cooktop extractor on)
24V DC
100 mA
Home Out Electrically isolated contact for cont-
rolling external devices depending on
the operating status of the cooktop
extractor (cooktop extractor on: con-
tact closed)
Maximum
250 VAC/ 30
VDC, 2.5 A
Tab. 6.3 Switch contacts
INFO
The Home In contact can be used for external
safety devices (e.g. window contact switches).
If the switch is open, the cooktop extractor is
out of operation.
X
X
Ensure that the control unit is disconnected from the
power supply.
Preparing the universal control unit
X
X
Remove the screws from the control unit.
X
X
Lift up the cover.
1
2
4
3
Abb. 6.29 Open the control unit’s cover
[1]
Cover
[2]
Electronic unit
[3]
Base unit
[4]
Switch contact clamp
INFO
The electronic unit [2] can contain residual
charge. You must therefore be careful not to
touch the exposed contacts on the electronic
unit!
Содержание CKASE