background image

EN

23

Assembly

www.bora.com

[1] 

Cooktop

[2] 

Suction opening

[3] 

Air inlet nozzle

[4] 

Stainless steel grease filter

[5] 

Worktop cut-out

[6] 

Mounting bracket

For surface installation

X

X

Make sure that the sealing tape of the cooktop is 

 resting on the worktop.

For flush installation

X

X

Make sure that the sealing tape of the cooktop is 

sealed well all the way round.

1

2

Fig. 6.17  Height adjustment plates

[1] 

Cooktop

[2] 

Height adjustment plates

X

X

If necessary insert height adjustment plates [2].

X

X

Fasten the cooktop using the mounting brackets [6] at 

the worktop.

X

X

Afterwards, insert the stainless steel grease filter [4] 

and air inlet nozzle [3].

X

X

Seal the surrounding gap with a black heat-resistant 

silicone sealing compound.

6.7  Installing exhaust air duct variant 

(BHA)

INFO 

National and regional laws and regulations must 

be followed when executing the exhaust air duct. 

Sufficient intake air must be provided.

6.7.1  Using the cooktop extractor with a 

fireplace which does not depend on 

room air

Fireplaces depending on room air (e.g. gas, oil, wood 

or coal-fired heaters, continuous-flow water heaters, 

 instantaneous water heaters) draw in air from the room in 

which they are installed and discharge the exhaust fumes 

to the outside via an exhaust system (e.g. chimney). 

When the cooktop extractor is used for exhaust air 

 operation, it draws in air from the room it is installed in 

and from neighbouring rooms. If there is insufficient air, an 

underpressure will occur. Toxic gases could be drawn out 

of the chimney or extraction duct and back into the room.

X

X

Hang the frame of the flexible duct into the retaining 

groove on the activated charcoal filter housing [2].

X

X

Make sure that the two lateral position shackles [1] are 

in the guide.

X

X

Slide the frame [3] up until the bottom lock [4] and the 

upper lock engage in the middle.

X

X

Make sure that the frame is fitted all around in the 

groove of the activated charcoal filter housing.

1

2

Fig. 6.15 

Inserting the activated charcoal filter

[1] 

Housing cover of the activated charcoal filter

[2] 

Activated charcoal filter

X

X

Remove the packaging from the activated charcoal 

filters.

X

X

Insert the two activated charcoal filters [2] from below.

X

X

Note the flow direction of the filter. This is indicated by 

an arrow.

X

X

Close the cover to the housing [1].

5

4

3

2

1

6

5

1

Fig. 6.16  Securing the cooktop in the middle

Содержание BHA

Страница 1: ...BHASUMEN 005 www bora com Operating and assembly instructions BHAS BHA BHU BORA Basic Hyper glass ceramic cooktop with cooktop extractor exhaust recirculation EN...

Страница 2: ...ntents are prohibited unless expressly authorised These operating and installation instructions have been drawn up with the greatest of care But it cannot be ruled out that subsequent technical modifi...

Страница 3: ...ooktop extractor with a fireplace which does not depend on room air 23 6 8 Establishing the power connection 28 6 9 Handover to user 29 7 Operation 30 7 1 Switch on off the cooktop and cooking zone 30...

Страница 4: ...he proper electrical installation and commissioning Gas specialists The gas connection may only be established by certified engineers They also assume responsibility for proper installation and commis...

Страница 5: ...ighted with symbols and signal words Safety and warning information is structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Consequences of non compliance X X Measures to...

Страница 6: ...h hot cooking surfaces is not possible X X Do not place any objects on the operating panel or the cooktop extractor air inlet nozzle X X Switch off the appliance after use X X Keep pets away from the...

Страница 7: ...X X When using recirculation mode ensure a sufficient supply of fresh air e g by opening a window X X Ensure a normal and comfortable room climate humidity of 45 60 e g by opening natural ventilation...

Страница 8: ...acted from the chimney or outlet duct into the living area X X Make sure that there is always a sufficient air supply WARNING Risk of burns from hot objects The cooktop and its exposed parts are hot w...

Страница 9: ...stainless steel grease filter 2 4 Safety Instructions Installation The appliance must only be installed and assembled by trained specialists who are familiar with and comply with the standard nationa...

Страница 10: ...ct stripping of the connection cable to external switching devices results in a risk of electric shock X X Ensure that the stated stripping lengths are adhered to Special safety information for exhaus...

Страница 11: ...e power supply cable This may only be done by an authorised member of the After Sales Service team 2 8 Use as intended The appliance cannot be used at altitudes above 2 000 m metres above sea level Th...

Страница 12: ...mption Cooking zone 1 210 mm 187 6 Wh kg Cooking zone 2 140 mm 177 5 Wh kg Cooking zone 3 210 mm 219 7 Wh kg Cooking zone 4 140 mm 181 2 Wh kg Total 191 5 Wh kg Extraction system BHA Maximum flow volu...

Страница 13: ...3 7 BHU Device dimensions side view 89 100 222 484 596 15 5 647 6 196 Fig 3 4 Device dimensions with cable extension BHA BLAVH1 Device dimensions BHU 380 515 650 120 253 760 476 R 3 275 142 Fig 3 5 B...

Страница 14: ...asured electric power input at best efficiency point WBEP 171 2 W Time increase factor f 1 4 Lighting Lighting efficiency LEhood lx W Lighting efficiency class Nominal power of the lighting system WL...

Страница 15: ...smoke or exhaust air flue that is not in operation the installation must be checked and approved by a qualified heating engineer Recirculated air mode The air suctioned away by the cooktop is purifie...

Страница 16: ...ive timer run down Off Timer off Timer display 0 1 99 Set minutes for short time egg timer or automatic cut off 00 Timer on no time set Tab 5 1 Meaning of displays Touch control The operating panel is...

Страница 17: ...inutes 5 3 How the cooking zone works Under the cooking zone is a radiant heating element with a heating tape When the cooking zone is switched on the heating tape generates radiant heat which directl...

Страница 18: ...y The filter service display becomes active after the cooktop extractor has operated for 150 hours The activated charcoal filters have reached the end of their service life with recirculation only and...

Страница 19: ...ake sure it is complete X X If there are any missing or damaged parts please notify BORA Customer Services immediately X X Do not under any circumstances install parts which are damaged X X Dispose of...

Страница 20: ...that it can be removed for maintenance work Q Q To ensure sufficient cooktop ventilation a minimum distance of 15 mm to the bottom edge of the cooktop is to be observed Q Q The drawers and or shelves...

Страница 21: ...the height of the rear wall so that the furniture body is closed to the front 6 x 5 Fig 6 10 Cut out and connection bores X X With surface installation attach the included sealing tape 2 on the unders...

Страница 22: ...the two outer locks 1 and the middle lock 2 click 2 4 3 1 Fig 6 14 Hooking in the frame of the flexible duct 1 Position shackles 2 Retaining groove on the activated charcoal filter housing 3 Flexible...

Страница 23: ...s flow water heaters instantaneous water heaters draw in air from the room in which they are installed and discharge the exhaust fumes to the outside via an exhaust system e g chimney When the cooktop...

Страница 24: ...00 mm Fig 6 18 Incorrect exhaust air system installation Fig 6 19 Correct exhaust air system installation X X When running the cooktop extractor in the room in which a fireplace is installed make sure...

Страница 25: ...um cross section of the exhaust air ducts must be 176 cm2 This equates to a cylindrical tube with a diameter of 150 mm Q Q The maximum exhaust air duct length is 6 m Q Q Planning information for the i...

Страница 26: ...ings 2 2 2 1 Fig 6 30 Engaging the airflow assembly 1 Airflow assembly 2 Openings X X Now move the airflow assembly 1 to the right until it engages fully into the slot of the opening 2 2 1 Fig 6 26 Re...

Страница 27: ...Stainless steel grease filter 5 Worktop cut out 6 Exhaust air arc 7 Exhaust air duct 8 Mounting bracket 1 1 1 Fig 6 31 Position lock 1 Shackles for transport and position lock X X Press the two shackl...

Страница 28: ...afety and warning information see Safety chapter X X Observe all national and regional laws and regulations as well as the supplementary regulations of the local utility companies INFO The power conne...

Страница 29: ...the cable routing to the rear X X Make sure that the cable is not clamped or damaged and cannot touch any hot parts of the cooktop X X Verify that the installation was done correctly X X Switch on th...

Страница 30: ...o power level 9 X X If one cooking zone is operated with the P power setting then the operation of the second cooking zone on this side is possible at a maximum of power level 5 X X If power level 5 i...

Страница 31: ...ay the set time is displayed and the cooking zone indicator light flashes X X Press until the timer display shows 00 Switching on the automatic pre cook valve X X Press the cooking zone button e g for...

Страница 32: ...e is run through Fig 7 2 Fan level sequence 7 1 10 Activating deactivating the child safety lock Activating the child safety lock INFO If a cooking zone indicator alternately shows L and H this means...

Страница 33: ...layed or X X press or several times until the fan level indicator 0 is displayed When the fan level indicator displays 0 the cooktop extractor is switched off automatically after a few seconds 7 3 Pay...

Страница 34: ...use any aggressive acidic or alkaline cleaning agents 8 2 Maintaining the cooktop X X Do not use the cooktop as a worktop or shelf X X Do not push or pull cookware across the cooktop X X Always lift...

Страница 35: ...air guiding housing Greasy deposits and limescale residues from the cooking vapour can accumulate on the surface of the air guiding housing Regular thorough cleaning see Table 7 1 is thus necessary T...

Страница 36: ...fan level indicator indicates F filter service display BAKF activated charcoal filters can be pur chased from your specialist You can also contact BORA on its homepage http www bora com X X Make sure...

Страница 37: ...the activated charcoal filter housing cover in the centre until the middle lock 3 engages X X Press the activated charcoal filter housing cover on the sides and close the outer locks 1 until they eng...

Страница 38: ...the fan level indicator One or more sensor buttons are covered e g due to finger contact or by objects placed on them Clean the control panel or remove objects see Device description chapter ER03 is s...

Страница 39: ...ally friendly disposal Disposal of transport packaging INFO The packaging protects the device from damage in transport The packaging materials have been selected from environmental and disposal perspe...

Страница 40: ...BORA Expressly not covered by the BORA manufacturer s warranty are Q Q BORA products that were not sold by authorised BORA dealers Q Q Damage caused by non adherence to the operating instructions inc...

Страница 41: ...EN 41 Notes www bora com 12 Notes...

Страница 42: ...EN 42 Notes www bora com...

Страница 43: ......

Страница 44: ...derndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Innstra e 1 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora co...

Отзывы: