Operating manual for DGM Modular | DOC02389740-0006 | 2021-07 | V1.70 EN
85
No.
Error name
Description of error
Possible causes/remedy
46
Motor parameters
Plausibility check for motor parameters failed
Parameter set not OK
47
Drive controller parameters
Plausibility check for drive controller
parameters failed
Parameter set not OK, motor type 33.001
and control method 34.010 not plausible.
48
Type plate data
No motor data entered
Please enter the motor data according to
the type plate
49
Power class restriction
Max. overload of the drive controller
exceeded for more than 60 sec.
Check application / reduce load / use
larger drive controller.
53
Motor tipped
Only for synchronous motors, field
orientation lost
Load too high. Optimise controller
parameters.
Tab. 12: Error detection
*
In exceptional cases, the error may be displayed erroneously when idling (very low motor current) with synchronous motors.
Set parameter 33.016 accordingly when the phases or motor connections are connected correctly.
**
Should the error occur again, depending on frequency, it can only be acknowledged after the following times:
1 -3
acknowledgements
permitted =
4 -5
acknowledgements
permitted =
> 5
acknowledgements
permitted =
1 s waiting time
5 s waiting time
30 s waiting time
The number of acknowledgements is deleted after 120 s without any errors!
Содержание DGM MPM
Страница 1: ...Operating manual for DGM Modular DOC02389740 0006 2021 07 V1 70 EN 1...
Страница 2: ...2 Operating manual for DGM Modular DOC02389740 0006 2021 07 V1 70 EN...
Страница 3: ...Operating manual for DGM Modular DOC02389740 0006 2021 07 V1 70 EN 3...
Страница 98: ......
Страница 102: ......
Страница 104: ......
Страница 105: ...Operating manual for DGM Modular DOC02389740 0006 2021 07 V1 70 EN 101...
Страница 106: ......
Страница 107: ...Operating manual for DGM Modular DOC02389740 0006 2021 07 V1 70 EN 103...