15.3.1
Digital Signal
The signals selected for parameters
Op. Mode Digital Output 1
530,
Digital Opera-
tion
554 and
Op. Mode Digital Output 3
532 can be linked with inverter functions.
Signal at digital output 1
175 - Digital Signal 1
The Signal which is selected via
Op. Mode Digital Out-
put 1
530.
Signal at multifunction output MFO1
176 - Digital Signal 2
The Signal which is selected via
Digital Operation
554.
Set
Operation Mode
550 = 1 - Digital.
Signal at digital output 3 (relay output)
177 - Digital Signal 3
The Signal which is selected via
Op. Mode Digital Out-
put 3
532.
With expansion module:
Signal at digital output 1 of an expansion module
181 - Digital Signal 4,
EM-Module
The signal, which is selected via
Op. Mode EM-
S1OUTD
533.
Signal at digital output 2 of an expansion module
182 - Digital Signal 5,
EM-Module
The signal, which is selected via
Op. Mode EM-
S2OUTD
534.