24
INSTALLATION
The.appliance.must.be.installed.by.qualified.
staff.working.in.accordance.with.the.regula-
tions. in. force.Before. installing,. ensure. that.
the.appliance.is.correctly.preset.for.the.local.
distribution. conditions. (gas. type. and. pres-
sure).The. presettings. of. this. appliance. are.
indicated. on. the. nameplate. shown. on. the.
cover.This.appliance.is.not.connected.to.a.flue.
gas.extractor.device..It.must.be.installed.and.
connected.in.accordance.with.the.regulations.
in.force.This.appliance.may.only.be.installed.
and.may.only.operate.in.rooms.permanently.
ventilated.in.accordance.with.national.regula-
tions.in.force.
VENTILATION
The.rooms.in.which.gas.appliances.are.in-
stalled.must.be.well.ventilated.in.order.to.allow.
correct.gas.combustion.and.ventilation.
The.air.flow.necessary.for.combustion.is.at.
least.2.m
3
/h.for.each.kW.of.rated.power.
POSITIONING
Remove.the.packaging.accessories,.includ-
ing.the.films.covering.the.chrome-plated.and.
stainless.steel.parts,.from.the.cooker..Position.
the.cooker.in.a.dry,.convenient.and.draft-free.
place..Keep.at.an.appropriate.distance.from.
walls.which.may.be.damaged.by.heat.(wood,.
linoleum,.paper,.etc.).Ensure.that.the.gas.cyl-
inder.cupboard.(where.present).is.adequately.
ventilated.The.cooker.may.be.installed.alone.
or.between.two.kitchen.units;.in.this.case,.the.
sides.of.the.units.must.withstand.a.tempera-
ture.of.100.degrees.C.and.they.must.not.be.
higher.than.the.cooker.hob.
CONNECTING TO THE GAS SUPPLY
Before.connecting.the.cooker,.check.that.it.
is.preset.for.the.gas.to.be.used..Otherwise,.
make. the. conversion. as. described. in. the.
section. headed. "Adapting. to. different. gas.
types"..The.connection.is.on.the.right;.if.the.
pipe.has.to.pass.behind.the.cooker,.it.must.
be.kept.low.down.where.the.temperature.is.
about.50.degrees.C.
- Rigid connection (see Figure 3, diagram
D):
. The. connection. to. the. mains. gas. supply.
may.be.made.using.a.rigid.metal.pipe.(D)...
Remove.the.hose.connector.and.screw.the.
rigid.union.onto.the.threaded.connection.of.
the.gas.train..The.union.for.rigid.connection.
is.amongst.the.cooker.accessories.
- Connection using a rubber hose (see
Figure 3, diagrams B and C):
. Connect. a. rubber. hose. carrying. the. con-
formity.mark.currently.in.force.to.the.hose.
connector..The.hose.must.be.replaced.at.the.
date.indicated,.and.must.be.secured.at.both.
ends.using.standard.hose.clamps..It.must.be.
absolutely.accessible.to.allow.its.condition.
to.be.checked.along.its.entire.length.
- Connection using a metal hose (see
Figure 3, diagram D):
. Make. the. connection. using. a. hose. which.
complies.with.national.standards,.screwing.
it.onto.the.connector.with.a.ring.seal,.which.
is.delivered.amongst.the.cooker.accesso-
ries.
-.After.installation,.check.that.all.connections.
are.airtight.
-.For.operation.with.butane/propane,.check.
that.the.gas.pressure.is.as.indicated.on.the.
nameplate.
IMPORTANT:
-.Use.only.standard.rubber.hoses...For.LPG,.
use.a.hose.which.complies.with.the.national.
regulations.in.force.
-.Avoid.sharp.bends.in.the.pipe.and.keep.it.
well.away.from.hot.surfaces.
References. to. the. regulations. covering. the.
gas.connection.to.the.appliance:.ISO.7-1.
GAS CYLINDER CONNECTION
Make.the.connection.to.the.butane/propane.
cylinder.using.an.approved.hose.from.60.to.
70.cm.long,.following.the.route.shown.in.figure.
4..The.hose.must.not.touch.the.side.near.the.
oven..The.maximum.gas.cylinder.size.is.di-
ameter.31.cm.and.height.60.cm,.with.capacity.
from.10.to.13.kg.
Installation
GB
Содержание BI 960 YA L
Страница 43: ...43...
Страница 44: ...44 ED 15 04 2013 335173 02...