page 8
Rev. A, 03/04
Technical Data
For correct working of the
, always keep the
technical parameters as specified below. Any use of the
beyond the range of the technical parameters may cause a
damage, to which the guarantee will not be related.
If you use the Flydat above the temperature limits, the warning
message "OVER RANGE" will show on the display together
with the temperature the
has just measured.
The
will store this information. In this case, turn the
off in order to prevent its damage.
General parameters:
FLY
FLY
FLY
FLY
FLY
dat
dat
dat
dat
dat
TECHNICAL DATA
Technical data
Sensors inputs:
Measuring range:
-40°C to +1050°C by environmental
temperature 25°C
Accuracy:
+/- 5°C
Application:
Exhaust gas temperature (EGT),
cylinder head temperature (CHT)
Measuring range:
-20°C to +270°C
Accuracy:
+/- 2°C
Application:
Air temp., coolant temperature (2-stroke)
Oil temp., cylinder head temp. (912/914)
Measuring range:
0 to 10 bar
Accuracy:
+/- 0,2 bar
Application:
Oil pressure (912/914)
Measuring range:
500 to 9990 rpm
Accuracy:
+/- 10 rpm
Measuring range:
0 to 10 bar
Indicating range:
0,0 to 999,9 h (after 999,9 h change to zero)
Accuracy:
+/- 1 sec/h at operation without interuption
Hour meter
1 x input oil pressure pick-up
2 x input resistance thermometer (PT-100)
4 x input for thermo couple NiCrNi (type K)
1 x RPM input
Flydat Operator's manual
Power supply:
10,0 to 32,0 Volts
Current consumption:
0,25 Amp@14Volts (without signalisation)
Alarm Output
1 Amp max. (voltage output in compilance
with power supply)
Operating temperature:
-20°C to 70°C (-4°F to 158°F)
Storage temperature:
-30°C to 85°C (-22°F to 185°F)
Relative humidity:
95% without condensating
Load:
+/- 20g
Vibration:
1 to 200 Hz
Weight:
ca 0,5kg (1lbs)
Display:
LCD with green background ilumination
2 x 16 digits, size of type 8 mm
Fuse:
3A, 32 Volts
Design:
Plastic injection molded housing with
plexiglass front plate, easy to change
FLYDAT
®
6
Section