7.2 Starting with jump wires
Choose this type of starting if the starter battery is flat
and the machine cannot be started manually with the
recoil starter.
NOTICE!
A wrong connection will cause severe damage in the
electric system.
The auxiliary battery must have the same voltage as
the starter battery.
Loosen the hood fasteners (1) on both sides and remove the
fasteners (2) from both sides
Fold the hood back.
Remove the battery holder and take off the vibration damping
mat.
Check vibration damping mats, brackets and screw connec-
tions, replace if necessary.
Join the plus poles on external battery and starter battery
with the jump wire
Use the second jump start cable to connect the negative
poles on external battery and starter battery.
Start the engine as described in the chapter “Starting the
engine”.
When the engine is running remove the jump start cable from
the two negative poles first and from the positive poles after.
This work sequence is necessary to avoid short circuit
caused by contact between positive and negative
cables.
Close the hood again and ´fasten it with bolts.
Fig. 82
Fig. 83
Trouble shooting – Starting with jump wires
BPR 50/55 D / BPR 60/65 D
81