background image

 

Safety Information 

 

 WARNING!

 

Installation and removal of the unit and its accessories must be carried out by qualified personnel. You must read 
all of the Safety Instructions supplied with your equipment before installation and operation. 

 

 

Warnings: 

 

If the product does not work properly, please contact your dealer. Never attempt to disassemble the camera 
yourself. (We will not assume any responsibility for problems caused by unauthorized repair or maintenance.) 

 

This installation should be made by a qualified service person and should conform to all the local codes. 

 

When shipping, the camera should be packed in its original packaging. 

 

Make sure the power supply voltage is correct before using the camera. 

 

Do not drop the camera or subject it to physical shock. 

 

Do not touch sensor modules with fingers. If cleaning is necessary, use a clean cloth with a bit of ethanol and 
wipe it gently. If the camera will not be used for an extended period of time, put on the lens cap to protect the 
sensor from dirt. 

 

Do not aim the camera lens at the strong light such as sun or incandescent lamp. The strong light can cause 
fatal damage to the camera. 

 

Maintenance Precautions: 

 

If there is dust on the front glass surface, remove the dust gently using an oil-free brush or a rubber dust 
blowing ball. 

 

If there is grease or a dust stain on the front glass surface, clean the glass surface gently from the center 
outward using anti-static gloves or an oil-free cloth. If the grease or the stain still cannot be removed, use 
anti-static gloves or an oil-free cloth dipped with detergent and clean the glass surface gently until it is 
removed. 

 

Do not use organic solvents, such as benzene or ethanol when cleaning the front glass surface. 

 

Regulatory Compliance 

FCC Part 15 

This equipment has been tested and found to comply with the limits for digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense. 
This product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
This device may not cause harmful interference. 
This device must accept any interference received, including interference that may cause undesired operation. 

 

LVD/EMC Directive 

This product complies with the European Low Voltage Directive 2006/95/EC and EMC Directive 
2004/108/EC. 

WEEE Directive

–2002/96/EC 

The product this manual refers to is covered by the Waste Electrical & Electronic Equipment 
(WEEE) Directive and must be disposed of in a responsible manner. 
 
 

 
 
 

Содержание SD5SN-M-10162017

Страница 1: ...1 SD500 SDI IP SERIES IR PTZ CAMERA USER MANUAL Part One Camera User Manual VERSION SD5SN M 10162017 2017 Bolin Technology ...

Страница 2: ...USE SDI VIDEO OUTPUT 11 STARTING THE CAMERA 11 SETUP CAMERA ID BAUD RATE AND CONTROL PROTOCOL 12 CONTROLLING THE CAMERA 13 ADJUSTING AND SETTING WITH MENUS 13 THE ON SCREEN MENU CONFIGURATION 14 VIDEO FORMAT 18 USE IP VIDEO OUTPUT 22 SETTING CAMERA OVER THE LAN 22 ACCESSING YOUR CAMERA 22 INSTALLING THE ACTIVEX 23 DIMENSIONS 24 SPECIFICATIONS 25 ...

Страница 3: ... products or procedures described in the manual Best effort has been made to verify the integrity and correctness of the contents in this document but no statement information or recommendation in this manual shall constitute formal guarantee of any kind expressed or implied We shall not be held responsible for any technical or typographical errors in this manual The product appearance shown in th...

Страница 4: ... the center outward using anti static gloves or an oil free cloth If the grease or the stain still cannot be removed use anti static gloves or an oil free cloth dipped with detergent and clean the glass surface gently until it is removed Do not use organic solvents such as benzene or ethanol when cleaning the front glass surface Regulatory Compliance FCC Part 15 This equipment has been tested and ...

Страница 5: ...s 1080P 720P Zoom 20X 30X Support ONVIF Compliant Video Compression H 264 MJPEG RS485 RS422 Communication Auto compatible with PELCO D and VISCA Protocol Store image parameter iris white balance exposure picture setting to a specified preset 3D positioning 120dB true WDR Video Output SDI IP True Dual Output SDI IP Simultaneously Intelligent Adaptive IR Illumination up to 100Meters Outdoor Environm...

Страница 6: ...6 WHAT S IN THE BOX Accessories Optional ...

Страница 7: ...7 Camera Diagrams Camera Tail Cable All cables are tagged to indicate their functions separately The cables available may vary with the product model ...

Страница 8: ...el number and included contents against the packing list to ensure components are complete Camera Structure 1 Tail Cable 2 Security Lock 3 Camera Body Important Verify the bearing capacity of the mounted position Verify that the mounted position meets the bearing requirements Otherwise you are advised to reinforce the mounted position for the device weight For more information see the product data...

Страница 9: ...he cable or to apply various kinds of stress to the cable so that the signal can be transmitted along the cable smoothly Different cable types have different physical characteristics and the transmission length of the digital signal is not the same Recommended cable Transmission signal Transmission distance Belden 7731A 3G SDI 120 m 128 above the double shield 75 5 HD SDI 70 m Power Input Bolin PT...

Страница 10: ... PoE power up to the PTZ camera Connect this PoE injector to a network switch and then run Ethernet cable for data transmission and power up the PoE PTZ camera Specific model EX1000 SD500 Series for distance up to 100 meters NOTE Disconnect the power from the camera beforemounting Accessories such as the wall mount bracket and the pendant mount bracket may be necessary during mounting For their mo...

Страница 11: ...ting the Camera After you have mounted the camera properly connect the camera to power Each time the camera is powered on it will perform a self test to check the Pan Tilt Zoom PTZ function After self test you can operate the camera NOTE The self test process starts after the camera is powered up Please wait patiently When the operating temperature is lower than zero degrees Celsius the camera wil...

Страница 12: ...setting on the camera have to be the same as baud rate and camera ID setting on the system control keyboard The camera can auto detect the VISCA and PELCO D only need to set up the camera address and baud rate Connect the camera to a monitor There is an initial setting page displaying on the screen for 5 seconds when the camera is powered on On the page it shows the factory default setting of the ...

Страница 13: ...of the SDI or IP NOTE Regarding the camera ID and Baud Rate setting for the first communication setting you must match the control system or keyboard camera ID and Baud Rate setting to the cameras After communicating successfully in between the camera and the control you can modify the ID and baud rate of the camera using the keyboard By default the camera Baud Rate Controlling the Camera The oper...

Страница 14: ...5 0 1 5 3 4 5 6 7 5 9 10 5 EXIT WHITE BALANCE AWB MODE AUTO INDOOR OUTDOOR OPW ATW USER R GAIN 0 255 B GAIN 0 255 EXIT PICTURE APERTURE 0 15 EFFECT OFF B W NEG EXIT LENS PARAMETERS DIGITAL ZOOM OFF ON JOYSTICK RECOVER NONE AF AI A I A F A F RECOVER 0 255 A I RECOVER 0 255 FOCUS NEAR LIMIT 1cm 10cm 20cm 30m DAY NITE MODE AUTO DAY NITE AUTO ICR THRESHOLD 0 28 GAMMA AUTO NORMAL 1 5 ZOOM SPEED 1 8 PRE...

Страница 15: ... 3 9 15 18 dB SPEED Select the electronic shutter speed from the following 1 1 1 2 1 3 1 6 1 12 1 25 1 50 1 75 1 100 1 120 1 150 1 215 1 300 1 425 1 600 1 1000 1 1250 1 1750 1 2500 1 3500 1 6000 1 10000 sec IRIS Select the iris the following CLOSE F14 F11 F9 6 F8 0 F6 8 F5 6 F4 8 F4 0 F3 4 F2 8 F2 4 F2 0 F1 6 LEVEL Select the brightness level from 0 to 23 BACKLIGHT MODE When the background of the ...

Страница 16: ... joystick to the right to exit this level menu WHITE BALANCE Menu The WHITE BALANCE menu is used to select the white balance mode MODE white balance mode Select the white balance mode from the following AUTO IN DOOR OUT DOOR OPW One Push White Balan ce ATW Auto Tracing White Balance USER When you select USER R GAIN red gain and B GAIN blue gain appear You can select each item in the rang e from 0 ...

Страница 17: ...Color to Night mode Black White when the lighting condition is low enough the camera illuminator will be turned on automatically at Night mode When the camera is set to Day mode the camera will stay in Day mode Color no matter how low the lighting condition is the camera illuminator will not be turned on at Night The image may be too dark to be seen in a low light condition When the camera is set ...

Страница 18: ... and keyboard and IP control will be unable to communicate FLIP Select ON to flip the image if you need to lift the camera VIDEO FORMAT SDI IP True Dual Output You can have parallel SDI and IP video output Either SDI or IP video format can be set up independently for having dual output simultaneously SDI output Select the SDI video output format from the following B Class models 1080P 60 59 94 50 ...

Страница 19: ...functionalities Note The number of available presets may be limited by the head ins controllers and DVRs that are connected to your dome system PRESETS SETUP Preset is to store the PTZ information such as Pan and Tilt positions focal length etc under the specific condition and call the camera PTZ quickly to shoot to the specified location that you want the camera to move to Note Presets not only s...

Страница 20: ...to manage the tours Total of 4 tours can be managed SEQUENCE NUMBER The current tour number that you are managing DEFAULT DWELL Set the interval time between each of presets in the above tour the value can be selected from 3 to 255 sec EDIT SEQUENCE Set up the above tour 1 In the order of add each of preset and default dwell time to the tour 2 The tour path will be set based on the presets and def...

Страница 21: ...amera scan 1 Push the joystick to the right to enter this setting menu 2 Move the camera to the right limit position that you want and then call the preset 1 to save DEFAULT SPEED Set the interval time from left to right during Scanning and select value from 3 to 255 sec RUN CONTINOUSELY start the above scan EXIT Push the joystick to the right to exit this level menu IDLE TIMER If the camera stays...

Страница 22: ...for your camera after you log in Accessing Your Camera For camera models with IP output you can manage and control through the web interface from a PC System Requirements for Your PC Item Requirements Operating System Microsoft Windows 8 Windows 7 Windows XP 32 bit or 64 bit Microsoft Windows 7 32 bit isrecommended CPU 2 0 GHz or higher dual core Intel i3 CPU or higher are recommended Memory At le...

Страница 23: ... the ActiveX The following message will show in IE browser on first login Click Download to install Active X Click Run You may also click Save to download the file to your computer first Close the browser and follow the steps to complete the installation NOTE For your first login with Windows 7 if the system does not prompt you to install ActiveX follow these steps to turn off UAC Click the Start ...

Страница 24: ...24 Dimensions Unit mm ...

Страница 25: ...25 Specifications ...

Страница 26: ...26 ...

Страница 27: ...27 www bolintechnology com 2082 TECHNOLOGY LLC dba BOLIN TECHNOLOGY ...

Отзывы: