XF-300 Series High Volume Fume extraction systems 

Bokar International         www.bokar.com, 

www.No-Stat.com

, www.ZeroCharge.net 

Page 7 of 11 

III.  PACKAGING 

 

There are two boxes. One contains the system and the second one, one or two arms. 

 

XF-301 

XF-302 

Box #1 

1. 

XF-300

 – Base with XF-300-CF combined 

filter, pre-filter 

2.  Power cord 

3.  Manual 

4.  Guarantee card 

 

Box #2 

1. 

XF-A75ESD

 – 75 mm ESD Arm with Funnel 

Box #1 

1. 

XF-300

 – Base with XF-300 CF combined 

filter, pre-filter 

2.  Power cord 

3.  Manual 

4.  Guarantee card 

 

Box #2 

1.  Two 

XF-A75ESD

 – 75 mm ESD Arm with 

Funnel 

XF-301H 

XF-302H 

Box #1 

1. 

XF-300

 – Base with XF-300-HF HEPA/Gas 

filter, pre-filter 

2.  Power cord 

3.  Manual 

4.  Guarantee card 

 

Box #2 

1. 

XF-A75ESD

 – 75 mm ESD Arm with Funnel 

Box #1 

1. 

XF-300

 – Base with XF-300-HF HEPA/Gas 

filter, pre-filter 

2.  Power cord 

3.  Manual 

4.  Guarantee card 

 

Box #2 

1.  Two 

XF-A75ESD

 – 75 mm ESD Arm with 

Funnel 

 

IV.  UNPACKING 

 

Prior to use of the system, please check if the system is complete. Should you notice that any items 

are missing, please notify us, giving the details of model number, voltage, date of purchase, where 

purchased and what is missing. Missing items must be reported within 7 days from the date of purchase. 

 

WARNING 

When unpacking, please be careful and read the manual prior to turning the system 

“ON”. Please check that the voltage of the System corresponds with the voltage of 

your available supply. Connection to incorrect voltage supply may cause damage to 

the System! 

 

V.  SET-UP AND INSTALLATION 

 

PLACEMENT 

Three major considerations need to be addressed for proper placement of the central filtration unit. 

  Exhaust Port: The exhaust port is located on the bottom of the filtration unit, next to the on/off switch. 

When positioning the unit, make sure that the exhaust port is not blocked or that airflow from the 

exhaust port is not restricted in any way. Additionally, the on/off switch (located on the back of the 

filtration unit) must be readily accessible. 

  Unit Location: The filtration unit should be located so that it will not block aisleways or impede normal 

operating traffic or material handling pathways. It is important to position the unit in such a way that 

allows for proper clearance to remove the filter access cover and replace the filter as needed. 

Содержание XTRACTOR XF-300 Series

Страница 1: ...XF 300 Series High Volume Fume Extraction Systems P N X DOC154 20 Oct 10 Rev B 650 Scranton Pocono Hwy Covington Twp PA 18444 USA Tel 570 842 2812 Fax 570 842 4290 E Mail bokar bomir com www bokar co...

Страница 2: ...NG 7 V SET UP AND INSTALLATION 7 VI SYSTEM DESCRIPTION and APPLICATION 8 VII TECHNICAL SPECIFICATIONS 9 VIII OPTIONAL EQUIPMENT 10 I INTRODUCTION A cost effective unit capable of extracting fumes with...

Страница 3: ...XF 300 Series High Volume Fume extraction systems Bokar International www bokar com www No Stat com www ZeroCharge net Page 3 of 11 FIG 2 VIEW OF XF 300 Base Dimension...

Страница 4: ...f not closely followed may result in severe personnel injury or death Danger is not used for property damage unless personal injury risk is present PRECAUTIONS The following are general safety precaut...

Страница 5: ...workplace should be monitored with appropriate and adequate measuring detection devices to assure compliance with all applicable Health and Safety regulations Flammable vapors and gases i e Isopropyl...

Страница 6: ...RATION PACE FUME EXTRACTION SYSTEMS MUST NOT BE USED TO EXTRACT FUMES FROM THESE SUBSTANCES WARNING Use with inappropriate chemicals or substances failure to provide regular maintenance or other misus...

Страница 7: ...ails of model number voltage date of purchase where purchased and what is missing Missing items must be reported within 7 days from the date of purchase WARNING When unpacking please be careful and re...

Страница 8: ...d The pre filter is always on top and the blue side of the prefilter should be facing upward The direction of airflow is clearly marked on the filter cartridge Airflow is always in a downward directio...

Страница 9: ...bs 25 kg 200 cfm 340m3 h Radial Blower 115 or 230 52 Hi Efficiency 95 0 3 micron HEPA GAS 99 997 0 3 microns XF A75ESD 75 mm Arm with funnel 950 mm in length funnel 160 mm in diameter The measurements...

Страница 10: ...ty of units X KAR use a pleated synthetic media with a separation of typically 95 of particulate down to 0 8 microns In cases where larger amounts of sub micron particulate are generated a higher effi...

Страница 11: ...ailable for more demanding or diverse applications All filters are produced in accordance with ISO9002 with micron filtration complying with BS3928 A certificate of conformity for each filter is avail...

Отзывы: