DANGER 

NEVER USE XTRACTOR FUME EXTRACTION SYSTEMS TO EXTRACT FUMES FROM 

HIGHLY FLAMMABLE LIQUIDS AND GASES SUCH AS ETHER, GASOLINE (PETROL) AND 

OTHERS. RISK OF SERIOUS INJURY, DEATH, FIRE OR EXPLOSION MAY RESULT. 

 

CERTAIN  AIRBORNE CONTAMINANTS SUCH AS METHYL ETHYL KETONE, 

CYCLOHEXONE, OZONE AND OTHERS, WHEN CONTACTED WITH ACTIVATED CARBON, 

CAN UNDERGO OXIDATION, DECOMPOSITION OR POLYMERIZATION RESULTING IN 

EXOTHERMIC REACTIONS OR HEAT GENERATION. PACE FUME EXTRACTION SYSTEMS 

MUST NOT BE USED TO EXTRACT FUMES FROM THESE SUBSTANCES. 

 

WARNING 

Use with inappropriate chemicals or substances, failure to provide regular maintenance or other 

misuse of your Fume Extraction System may result in contaminated air being re-circulated into 

the work environment. 

 

CAUTIONS 

Utilize all standard electrical safety precautions when using this or any other electrical equipment. 

 

DANGER 

POTENTIAL SHOCK HAZARD – All repairs made on this product should be performed by qualified service 

personnel  only. Line voltage parts will be exposed when equipment is disassembled. Service personnel 

must avoid contact with these parts when troubleshooting. 

 

NOTES 

To insure continued peak performance, use genuine XTRACTOR replacement parts. 

 

Содержание XTRACTOR XF-300 Series

Страница 1: ...XF 300 Series High Volume Fume Extraction Systems P N X DOC154 20 Oct 10 Rev B 650 Scranton Pocono Hwy Covington Twp PA 18444 USA Tel 570 842 2812 Fax 570 842 4290 E Mail bokar bomir com www bokar co...

Страница 2: ...NG 7 V SET UP AND INSTALLATION 7 VI SYSTEM DESCRIPTION and APPLICATION 8 VII TECHNICAL SPECIFICATIONS 9 VIII OPTIONAL EQUIPMENT 10 I INTRODUCTION A cost effective unit capable of extracting fumes with...

Страница 3: ...XF 300 Series High Volume Fume extraction systems Bokar International www bokar com www No Stat com www ZeroCharge net Page 3 of 11 FIG 2 VIEW OF XF 300 Base Dimension...

Страница 4: ...f not closely followed may result in severe personnel injury or death Danger is not used for property damage unless personal injury risk is present PRECAUTIONS The following are general safety precaut...

Страница 5: ...workplace should be monitored with appropriate and adequate measuring detection devices to assure compliance with all applicable Health and Safety regulations Flammable vapors and gases i e Isopropyl...

Страница 6: ...RATION PACE FUME EXTRACTION SYSTEMS MUST NOT BE USED TO EXTRACT FUMES FROM THESE SUBSTANCES WARNING Use with inappropriate chemicals or substances failure to provide regular maintenance or other misus...

Страница 7: ...ails of model number voltage date of purchase where purchased and what is missing Missing items must be reported within 7 days from the date of purchase WARNING When unpacking please be careful and re...

Страница 8: ...d The pre filter is always on top and the blue side of the prefilter should be facing upward The direction of airflow is clearly marked on the filter cartridge Airflow is always in a downward directio...

Страница 9: ...bs 25 kg 200 cfm 340m3 h Radial Blower 115 or 230 52 Hi Efficiency 95 0 3 micron HEPA GAS 99 997 0 3 microns XF A75ESD 75 mm Arm with funnel 950 mm in length funnel 160 mm in diameter The measurements...

Страница 10: ...ty of units X KAR use a pleated synthetic media with a separation of typically 95 of particulate down to 0 8 microns In cases where larger amounts of sub micron particulate are generated a higher effi...

Страница 11: ...ailable for more demanding or diverse applications All filters are produced in accordance with ISO9002 with micron filtration complying with BS3928 A certificate of conformity for each filter is avail...

Отзывы: