XF-300 Series High Volume Fume extraction systems
Bokar International www.bokar.com,
, www.ZeroCharge.net
Page 8 of 11
•
Proximity to the work area: The filtration unit should be placed as close to the work area as possible.
If using a flex hose, it is advantageous to keep the length of flex hose as short as possible. Do not
kink or create any sharp bends in the flex hose, as this will reduce airflow.
POWER
The XF-300 Series will plug into a standard 110 volt or 230 volt electrical outlet, depending on the model
you purchased. Be sure the unit you have is rated for the intended power supply.
WARNING
Failure to supply the correct voltage to the unit will result in damage to the motor.
FILTERS
Before operating the unit, make sure the filter is correctly positioned. The pre-filter is always on top and the
blue side of the prefilter should be facing upward. The direction of airflow is clearly marked on the filter
cartridge. Airflow is always in a downward direction for the XF-300.
INLET CAPS
If an inlet port is not connected to a collection device, it must be covered with the inlet cap provided.
VI. SYSTEM DESCRIPTION and APPLICATION
Connecting One or Two XF-75A-ESD Arms with Funnel
1. Slide the narrow end of the XF-A75-ESD Arm over one inlet port on the XF-300 Base.
2) Secure the Arm to the inlet of the XF-300 with the Arm clamp (provided).
3) Position the Arm for maximum extraction performance.
4) If using one Arm, make sure the inlet cap covers the unused inlet.
5) Repeat steps 1 through 3 to attach second Arm.
XF-301 XTRACTOR – XF-300 Base one
XF-A75ESD Arm with Funnel
XF-302 XTRACTOR – XF-300 Base two XF-A75ESD
Arm with Funnel
NOTE: XF-300 Base can be placed on the bench top or located under a workbench, depending on operator
preference.