Nilfisk-Advance A/S
Sognevej 25
DK-2605 Brøndby
Denmark
Tel.: +45 43 23 40 50
Fax: +45 43 43 77 00
[email protected]
www.nilfisk.com
ATTENTION!
Do not use the machine before you have read and understood the User Manual
2. Fill the tank with a solution suitable
for the work to be performed.
Always follow the dilution instructions
on the label of the chemical product
used to prepare the solution. Its tem-
perature must not exceed 40°C.
1 Disconnect the battery charger cable
from the electrical main.
3. Install the squeegee and fasten it
with the handwheels, then connect
the vacuum hose to the squeegee.
4. Place the brush or the pad-holder
under the deck. Use the appropriate
brush to clean the floor.
17. Charge the batteries: Connect the
battery charger cable to the
electrical main
15. Check and clean the squeegee
blades
16. Clean the machine using a damp
cloth and where needed use a
neutral cleaning product
18. Park the machine with the recovery
tank cover open
12.
Clean the filter by: Remove the
transparent cover and the gasket
10.
At the end of the work.
Empty
the recovery tank with the hose. Then
empty the solution tank with the
trasparent hose
11. Wash with clean water the recovery
tank and the vacuum grid
13. Remove the brush/pad and clean
them
14. Take the squeegee off and remove
debris.
7. Press the solution flow control
switch as necessary, depending on the
type of cleaning to be performed
5. Switch on the brush and vac motors
to activate the machine
6. Press the handle switch to engage
the brush and run the machine
8. Lower the squeegee with the lever.
9. Press the enabling push-button together
with the brush levers for starting floor
cleaning. If solution applied flows outside
the brush housing during use, reduce the
flow of solution.
If the machine has been used until the Red light illuminates on the battery level indicator on the machine, a full recharge of the batteries (10-12 hours) will be required. Failure to
carry out this this procedure may cause damage to the batteries. Charging the batteries after every use is recommended.
PLEASE ENSURE RED SOCKET IS LEFT DISCONNECTED AFTER RECHARGE IF THE MACHINE IS NOT TO BE USED ON A DAILY BASIS
OPERATING GUIDELINES
SC400
All manuals and user guides at all-guides.com
all-guides.com