0010 00
BOH-PM-13-2
Chapter 2 Rev. 0.01
0010 00-2
Establishing Power Supply
The Office Module supplies an electric adapter cord and 30A 120V outlet to connect to electrical supply
source.
1. Before any electrical connections are made, enter the Office Module and ensure the main
circuit breaker and all the circuit breakers are turned off. Also ensure the main power source
has been turned off.
2. Establish a grounded connection at the electrical supply source.
3. Insert angle plug cord (yellow end) into office module.
4. Connect the white end of the cord to the power source (extension cord likely required).
5. Turn on the main power source. Then turn on all office module circuit breakers.
WARNING
Ensure all circuit breakers and the main power source is switched off before making electrical
connections. Ensure the proper cable connectors are installed by a certified electrician Army
MOS 21R and match the power source. An electrical ground must be established first to prevent
electrical shock to personnel. Consult ARMY TM 5-811-3 Chapter 2 and MIL-HDBK-633A.
Turn off all breakers
before connecting
power source