Technical data C 16 N...C 30 N, part 1
Type
C 16 N
C 20 N
C 25 N
C 30 N
Dimensions
– Width
[inch]
28.4
28.4
28.4
28.4
– Depth
[inch]
41.6
41.6
41.6
41.6
– Height
[inch]
68.3
68.3
68.3
68.3
Weight
– silenced
[lbs.]
–
–
–
–
– super silenced
[lbs.]
1060
1082
1111
1193
Max. sound pressure level
[±3 dB(A)]
accord. to DIN 45635, part 13
– silenced / super silenced
[dB(A)]
63
65
68
69
Reference surface measure
– silenced / super silenced
[dB(A)]
16
16
16
16
Sound power level
– silenced / super silenced
[dB(A)]
79
81
84
85
Compressor
max. final compression temperature
[°F]
+ 230
+ 230
+ 230
+ 230
Volume flow according to
ISO 1217 appendix C at:
– p
max
= 100 psig
[cfm]
70.76
95.47
116.06
135.51*
– p
max
= 115 psig
[cfm]
66.75
90.07
109.49
127.84*
– p
max
= 150 psig
[cfm]
57.57
79.47
95.72
113.36*
– p
max
= 190 psig
[cfm]
47.68
66.75
81.94
95.70*
Drive motor
Rated power
[Hp]
15
20
25
30
Electrical power intake dryer
[Hp]
–
–
–
–
Nominal speed
– 60 Hz
[rpm]
3600
3600
3600
3600
Protection type
TEFC
TEFC
TEFC
TEFC
ISO class
F
F
F
F
Electrical connection
Mains voltages compressor
1)
[V]
1)
Standard equipment. Mains voltages and frequencies are specified on a plate in the switch cabinet.
208-230 /
208-230 /
208-230 /
208-230 /
460 / 575
460 / 575
460 / 575
460 / 575
Frequency
[Hz]
60
60
60
60
Fuse protection
2)
for 200 V
[A]
2)
Use fuse RK 5 only.
* By using 208 V mains voltage: Volume flow decreases by 10 %.
50
70
90
100
Fuse protection
2)
for 208 V
[A]
50
70
90
100
Fuse protection
2)
for 230 V
[A]
50
60
70
100
Fuse protection
2)
for 460 V
[A]
30
30
40
50
Fuse protection
2)
for 575 V
[A]
20
30
30
40