background image

4.3 - Irig B / AFNOR coded time output (Independent version)

An independent clock can synchronise another IRIG B / AFNOR receiver.

Connect the 2 wires for the IRIG B/AFNOR signal to terminal block (L) on the

transmitting World clock, as well as to terminal (L) on the world receiver clock.

5 - DISPLAYS AND TESTING CONFIGURATION

For models 3 to 6 cities, each display is linked to a keyboard with 2 keys “+”
and “Select” to ensure programming and light intensity adjustment (4 levels).
For the “radio quartz independent” clock versions an additional keyboard is
positioned on the lefthand side of the box in order to adjust the time base (no
keyboard for IRIG B/AFNOR coded time receiver versions).

For IRIG B/AFNOR coded time versions :
configure the coded time generator (master clock or world clock) so that it
distributes GMT time. Do not programme the summer / winter time change.

Carry out installation and electrical connections before setting the time.

7

World clock mas ter

World clocks re ceiver

View from above

2 adjustment keys on the left-hand
side of the box. Independent quartz
model only

Keyboard with 2 keys “+” and “Select” for
each display (interior edge).

Содержание WORLD STYLE

Страница 1: ...io Irig B Afnor receiver On receipt check carefully that the product has not been damaged during transport and if necessary submit reservations to the carrier B P 1 49340 TR MENTINES FRANCE T l 33 2 4...

Страница 2: ...dependent version 7 5 DISPLAYS AND TESTING CONFIGURATION 7 5 1 Setting the time 8 Independent clock 8 IRIG B AFNOR receiver clock 8 5 2 Configuration menu of displays 8 5 2 1 Selecting the summer wint...

Страница 3: ...clock is connected to a mains power supply its installation must comply with standard IEC 364 NFC 15 100 for France n Indoor assembly IP 41 n The power supply for this clock should include a max 6A l...

Страница 4: ...the angle of reading 120o and possible reflections of light This clock is intended for installation indoors Fixing holes position of wall mounting plate Lengths in mm H G E 3 cities 176 5 420 773 4 ci...

Страница 5: ...ough the cable carrier F 4 ELECTRICAL CONNECTIONS 4 1 Power supply n Remove the black protective cover on the terminal block P n Connect the 230 Volts 50 60 Hz mains power supply depending on the mode...

Страница 6: ...structions for positioning the antenna n With a France Inter DCF radio antenna or FI DCF output on MIC GPS connect the 2 wires of the antenna or the Mic GPS to the radio input of the world clock Refer...

Страница 7: ...r the radio quartz independent clock versions an additional keyboard is positioned on the lefthand side of the box in order to adjust the time base no keyboard for IRIG B AFNOR coded time receiver ver...

Страница 8: ...from the master clock or World clock n Warning in the event of loss of AFNOR signal each display will operate independently for 1 hour before the readout disappears Only the separating dots in the cen...

Страница 9: ...in October The time change takes effect at 1 o clock GMT In March at 2 o clock local time forward 1 hour In October at 3 o clock local time back 1 hour Nota Europe is divided in 3 hourly groups Conti...

Страница 10: ...then press the key for 3 seconds for each keyboard situated below the display Display 2nd digit flashes to start up programming 2 Press to select the time change month choice of 1 to 12 e g March 3 f...

Страница 11: ...of last 2 digits 11 Press to scroll through the date changes choice 1 to 31 e g March 10 12 Confirm with Select To enter the second time change date go back to the step 2 either go to following step...

Страница 12: ...ast 5th as max 5 weeks in the month Change at fixed date on 12 April April programme 4 12 date 12 after confirming F NB the change from summer time to winter time is at the end of the year October for...

Страница 13: ...ifference 12 30H to 12 30H in 30 minute steps using the key then confirm with the Select key Example for Paris program 1 hour GMT 5 3 Testing Having adjusted the time difference display of all diodes...

Страница 14: ...ifference is of one hour but at Sydney it is the summer and the time difference is of 10 hours more one hour of time difference summer winter that is to say 11 hours CITY Reference zone Display Time d...

Страница 15: ...le mode 12 PARAGUAY Fixed date change every year 04 TEHERAN Fixed date change every year 3 30 BOMBAY No change 5 30 Paris and the following cities Frankfurt Madrid Stockholm Oslo Zurich Milan Amsterda...

Страница 16: ...keyboard without opening the clock 1 keyboard per display IP box IP 41 Incline 5 Material aluminium Colour black polyurethane paint Shape injected rounded corners Fixing bracket wall hanging with 2 sc...

Страница 17: ...s d r a d n a t S European and French standards CE Electromagnetic compatibility directive 89 336 CEE radio electric disturbances produced by information processing units NF EN 50082 1 June 1992 low v...

Страница 18: ...ng conditions n Be careful that all displays have the same light intensity 8 BACKUP n The World clock is fitted with a device for storing the configuration parameters even in the event of an extended...

Страница 19: ...gramming in relation to the name of the city The time signal from the time base or the AFNOR signal must be GMT and not local time Check the time difference programmed n The time change was correct la...

Страница 20: ...20...

Отзывы: