3.1 - Wall support installation :
Having loosened screw (B), unhook the clock from its wall bracket, then
remove the connectors.
Fix bracket (A) to the chosen location on the wall after threading the cables
through the cable carrier (F).
3.2 - Ceiling bracket installation :
The ceiling hanging adjusts to bracket (A) in the same way as when
wall hanging. Warning: do not forget to first put the cables through
the conduit on the bracket before fixing.
Having loosened screw (B), unhook the clock from its wall bracket,
then remove the connectors.
Fix bracket (A) to the chosen location on the wall after threading the
cables through the cable carrier (F).
4 - ELECTRICAL CONNECTIONS
4.1 - Power supply
n
Remove the black protective cover on the terminal block (P).
n
Connect the 230 Volts 50/60 Hz mains power supply (depending on the
model) to the terminal block (maximum wire cross section 1.5 mm² with 5 mm
bare).
n
Replace the protective cover. Block the wires with cable clips.
N.B. :
The mains supply unit for this display must include a max. 6A
live/neutral interlocked circuit breaker.
This circuit breaker must be
switched off during maintenance.
The electronic card for each display is protected by a 0.8A 250 V fuse (F1).
The world clocks have been designed for a mains power supply of 230 Volts
± 10 % (depending on the model). For example, 230 V clocks will work
equally well in countries where the nominal mains voltage is 220 Volts or 240
Volts.
5
Содержание WORLD STYLE