6
C
Stainless steel
nut HU M8
Stainless steel 8 mm
tooth washer
Stainless steel
screw H M8x25
C
C
Horizontal bracket attachment
Vertical bracket attachment
Bracket
D
D
D
St. steel screw ST F M5-40
Single face cover
St. steel 6 mm flat washer
Stainless steel nut HM5
5/ Attach the bracket to the wall with
four 8 mm (HMT Led 15 and 20) or 10
mm (HMT Led 25) threaded rods plus
chemical sealing (recommended).
6/ Attach the double face support to
the bracket with the four 8 mm screws
(detail C). Remember to insert the
cables in the bracket.
7/ Open the clock, remove the glass
and unscrew the wall attachment parts.
8/ Attach the clock to the double face
support on the 4 screws ST F M5-40
(detail D). Place the 6 mm washers
(detail D) flat on the double face support
(and not inside the clocks) to move the
clocks sufficiently far away and facilitate
insertion of the cables. Screw in the 2
nuts at the top (D) without tightening,
move the clock away and insert the
cables.
9/ If cables are correctly positioned,
tighten the 4 nuts (D) of the readout.