13
8. Re-attach all other external cables and power cords to their
original position. Installation of the hardware is now complete.
Go to section 2.2 Adapter Configuration.
2.2 Adapter Configuration
Loading a Single Board
The BOCALANcard 2000 Plus is a software-configurable Ethernet
adapter. In order to change parameters, run the configuration
utility, BENCFG.EXE, to specify the following options:
I/O Base Address, Interrupt Number, Run Diagnostics, and
Boot ROM Address.
Loading Multiple Boards
To load more than one BOCALANcard 2000 Plus in your
machine, you must configure each one separately. Configure each
board to a different interrupt and I/O base address. Insert one
card and run BENCFG.EXE. When all cards have been correctly
configured, power down and re-insert all adapters. The network
driver must be loaded again for each new adapter board installed
in the system. For example, to load three boards in a NetWare
server environment, the following must be entered.
For first adapter board: LOAD NE2000.LAN int=X1 Port=Y1
For second adapter board: LOAD NE2000.LAN int=X2 Port=Y2
For third adapter board: LOAD NE2000.LAN int=X3 Port=Y3
Installation and Configuration