Page 5
Recommended Mounting Heights:
Distance from floor to bottom mounting screw holes of mounting
base.
Men's Washrooms ....................................................... 45-1/4'' (1150mm)
Women's Washrooms .................................................. 43-1/4'' (1100mm)
Children's Washrooms, ages 3-9 ................................ 31-1/4'' (795mm)
Children's Washrooms, ages 9-12 .............................. 35-1/4'' (895mm)
Children's Washrooms, ages 12-15 ............................ 39-1/4'' (995mm)
Children's Washrooms, ages 15-18 ............................ 43-1/4'' (1100mm)
For the Handicapped ................................................... 37-1/4'' (945mm)
Place mounting base on wall at the desired location of the installed dryer. See
recommended mounting heights.
Use the mounting base or the template provided with dryer to mark location of three
mounting screw holes and access hole for electrical wiring (if electrical supply is concealed
in wall and will enter dryer from back through mounting base).
NOTE
: Surface mounted electrical supply (line cord) is attached to dryer through hole in air
inlet/outlet grille in lower left corner.
Drill three holes for #10 (M4.8) diameter mounting bolts or screws (not furnished by
Bobrick).
For masonry walls provide three #10 expansion shields or anchors, then secure with three
#10 (M4.8) sheet-metal screws (not furnished). For plaster or dry wall construction, provide
concealed backing to comply with local building codes and secure with three #10 (M4.8)
round-head sheet-metal screws, or 3/16'' (5mm) toggle bolts (not furnished).
NOTE
: Use 1-3/4'' (45mm) screws.
Fasten mounting base securely to wall.
WARNING:
TURN ELECTRICAL POWER SUPPLY OFF BEFORE MAKING ELECTRICAL
CONNECTIONS.
DRYER MUST BE GROUNDED (EARTHED).
ELECTRICAL CONNECTION
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT
MUST BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN. WARNING; TURN
ELECTRICAL POWER SUPPLY OFF BEFORE MAKING ELECTRICAL CONNENTIONS.
Connect dryer to nearest distribution panel. Use wire as required by local electrical code. In
the United States and Canada use #12 wire or larger.
A fused means for disconnection in all poles must be provided in the fixed wiring in
accordance with the wiring rules.
For Model B-740 115V and B-748 115V Dryers:
Connect ground (earth) wire to ground
(earth) terminal on the mounting base marked
. Connect the black or Hot wire to terminal
Содержание AirCraft B-701
Страница 32: ...Page 26 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Automatic Dryer ...
Страница 33: ...Page 27 Schematic Diagram 208 240V Touch Dryer ...
Страница 42: ...Page 9 ...
Страница 50: ...Page 8 ...
Страница 58: ...Page 8 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Dryer ...
Страница 66: ...Page 8 ...