Page 20
Hair dryer.
Men’s Dressing Rooms ......................................................... 72'' (183cm)
Women’s Dressing Rooms .................................................... 64'' (163cm)
Children’s Dressing Rooms, ages 3-9 ................................... 45'' (114cm)
Children’s Dressing Rooms, ages 9-12 ................................. 52'' (132cm)
Children’s Dressing Rooms, ages 12-15 ............................... 58'' (147cm)
Children’s Dressing Rooms, ages 15-18 ............................... 63'' (160cm)
Drill four holes for 1/4" (6.4mm) diameter mounting bolts or screws (not furnished by
Bobrick).
Fasten mounting base securely to wall.
Place mounting base on wall at the desired location of the installed dryer. See
recommended mounting heights above. Use the mounting base or the template provided
with dryer to mark location of four mounting screw holes and hole for electrical wiring if
electrical supply is concealed in wall and will enter dryer from back through mounting base.
NOTE:
Surface-mounted electrical supply is attached to mounting base in lower right
corner. Flange of mounting base and bottom of cover are notched in lower right corner to
accommodate connection of electrical conduit.
WARNING:
TURN ELECTRICAL POWER SUPPLY OFF BEFORE MAKING ELECTRICAL
CONNECTIONS.
DRYER MUST BE GROUNDED (EARTHED).
ELECTRICAL CONNECTION.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT
MUST BE ISTALLED BY A QUALIFIED LICENSED ELECTRICIAN, WARNING: TURN
ELECTRICAL POWER SUPPLY OFF BEFORE MAKING ELECTRICAL CONNENTIONS.
Connect dryer to nearest distribution panel. Use wire as required by local electrical code. In
the United States and Canada use No. 12 wire or larger.
Wiring Instructions:
A fused means for disconnection in all poles must be provided in the fixed wiring in
accordance with the wiring rules.
For 115 Volt Dryers:
Connect ground (earthed) wire to ground (earthed) terminal marked
, the black or Hot wire to terminal marked L1 and neutral or white wire to terminal
marked N.
DEDICATED LINE IS REQUIRED FOR EACH 115 VOLT DRYER.
For 208
–240 Volt Dryers:
Connect ground (earthed) wire to ground (earthed) terminal
marked
and the 208-240 Volt wires to terminals marked L(L1) and N (L2).
Secure electrical wire in strain relief clamp provided on mounting base.
Содержание AirCraft B-701
Страница 32: ...Page 26 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Automatic Dryer ...
Страница 33: ...Page 27 Schematic Diagram 208 240V Touch Dryer ...
Страница 42: ...Page 9 ...
Страница 50: ...Page 8 ...
Страница 58: ...Page 8 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Dryer ...
Страница 66: ...Page 8 ...