Page 23
Provide framed opening in wall 13-3/4'' wide x 9-1/2'' high x 3-3/4'' deep (349 x 241 x
95mm) at the desired location of the installed dryer. See recommended mounting heights
above.
Frame the opening as shown in diagram to support recessed mounting box.
Place the recessed mounting box in wall and cut an opening in the framing to allow
clearance for electrical conduit and fittings at one of the three conduit knockout locations.
Fasten recessed mounting box to framing with minimum of four No. 10 (4.8mm) sheet metal
screws (not furnished by Bobrick). Make sure flanges of mounting box are completely flat
against finished wall surface. If necessary, use shims or spacers between mounting box
and framed wall opening to prevent distortion to box as it is fastened to framing.
Install electrical conduit from nearest distribution panel to recessed mounting box. Attach
conduit fittings to mounting box. Use wire as required by local electrical code. In the United
States and Canada use No. 12 wire or larger. Allow a minimum of 24'' (610mm) of wire to
remain in recessed mounting box for connection to dryer terminals.
INSTALLATION OF ALUMINUM BASE UNIT INTO RECESSED MOUNTING BOX.
Start installation of aluminum base unit into recessed mounting box by removing cover. To
loosen two cover bolts, insert Allen wrench, provided with dryer, into holes located on
bottom edge of cover. Make sure wrench fits into head of cover bolts and turn CLOCKWISE
until bolts stop turning. When both cover bolts are screwed in all the way, cover can be
removed.
To remove cover, place a hand on each side of cover and push up toward top of dryer
releasing cover from studs at top of aluminum base unit. Lift cover off base unit by pulling
forward at the bottom and upward at the same time.
Insert aluminum base unit into recessed mounting box and fasten to top and bottom flanges
of mounting box with the four 1/4-20 UNC (MG-1) screws provided.
WARNING:
TURN ELECTRICAL POWER SUPPLY OFF BEFORE MAKING ELECTRICAL
CONNECTIONS.
DRYER MUST BE GROUNDED (EARTHED).
ELECTRICAL CONNECTION.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODEE. UNIT
MUST BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN. WARNING: TURN
ELECTRICAL POWER SUPPLY OFF BEFORE MAKING ELECTRICAL CONNECTIONS.
Wiring Instructions:
A fused means for disconnection in all poles must be provided in the fixed wiring in
accordance with the wiring rules.
For 115 Volt Dryers:
Connect ground (earthed) wire to ground (earthed) terminal marked
, the black or Hot wire to terminal marked L1 and neutral or white wire to terminal
marked N.
Содержание AirCraft B-701
Страница 32: ...Page 26 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Automatic Dryer ...
Страница 33: ...Page 27 Schematic Diagram 208 240V Touch Dryer ...
Страница 42: ...Page 9 ...
Страница 50: ...Page 8 ...
Страница 58: ...Page 8 Schematic Diagram 115V Dryer Schematic Diagram 208 240V Dryer ...
Страница 66: ...Page 8 ...