Storage Precautions
• Storing your generator with fuel in the tank can pose a risk of gasoline
vapor ignition. It is important to reduce that risk by only storing the
generator in a well-ventilated area. Do not store next to any sources of
ignition. Such as a furnace or water heater.
• Avoid areas with high humidity. This can cause excessive rust that is
damaging to the generator.
• Place the generator on a level surface. Tilting or laying it on its side can
cause fuel or oil leakage.
• Be sure the fuel switch is in the “off” position.
Removal From Storage.
• Use the instructions outlined in the startup section of this manual
• If fuel was drained for storage, fill the tank with fresh gasoline.
• If the combustion chamber was coated with oil during storage, the
engine might smoke briefly at startup. This is normal and should clear
up within a few seconds.
Item
BNG5500iE
Engine
Gasoline Engine
Type
Single Cylinder. 4-stroke,-
Forced Air Cooling, OHV
Displacement
312 cc
Igniting System
CDI
Oil Capacity
0.8 Qt
Generator
Fuel Volume
13.5 Gal
Rated Frequency
50/60 Hz
Rated Voltage
230/120/240 V
Rated Output
Power
5 kW
Maximum Output
power
5.5 kW
DC
12/8.3 V/A
Gen Set
Length (mm)
24” (610)
Width (mm)
18.5” (470)
Height (mm)
21” (535)