| 13 |
BN Products-USA
www.bnproducts.com
• Replace the air filter every 25 hours.
• lf you have missed the scheduled time to maintain your engine, do it as
soon as possible.
A spot inspection should be performed before starting your generator. If the
maintenance cycle time has passed, the maintenance should be carried out as
soon as possible, according to the maintenance table.
Stop the engine before servicing and put the generator on a level surface. Never
run your machine in a poorly ventilated room or any other enclosed area, be
sure to keep good ventilation in the working environment. The exhaust from the
engine contains poisonous CO
2
, and inhalation can cause shock, unconscious-
ness, and even death.
Engine Oil Change
Drain the oil while the engine is warm to assure complete and rapid draining.
Engine Oil capacity: 0.8 Qtr
• Ensure the fuel shut-off switch is in the “off” position to prevent fuel
leakage.
• Place a suitable container next to the engine to catch the oil as it’s
draining.
• Remove the oil drain bolt and let the oil run into the container. It
may be necessary to tip the generator slightly to ensure all the oil has
drained.
• Reinstall the oil drain bolt, and with the engine in a level position, refill
the engine oil to the proper level.
• Wash your hands with soap and water after handling used oil.
• SAE oil viscosities are on the API label of the oil container. Therefore,
we recommend using API service category SJ or later (or equivalent)
oil.
• SAE 10W-30 is recommended for general use.