1.5 Basic connection method
1.5.1 Assembling and dis-assembling of the pickup
As shown in the figure, hold the connection part of top guide tray and pickup main body (stylus is downward), plug
in the mainframe's connecting socket according to the figure connecting line direction, press lightly to the end till
stable connection. When taking out, please disconnect pickup from connecting socket, then take the pickup out
from drive slowly. All the operation process should be careful to avoid pickup breakage.
Assembling and dis-assembling of the pickup
Note: 1. Pickup stylus is the key accessory of this instrument, please pay high attention to it when using.
2. During the process of pickup assembling and dis-assembling, please do not touch the stylus to avoid
breakage which would affect the measurement.
3. During the process of pickup assembling, please make sure that the connection is reliable.
1.5.2 Charger and battery charging
When the battery is low on the display or the tester cannot boot, charge in time. To charge, connect the charger to
220V/50Hz mains power, and then connect the charger plug into the micro USB socket at back of the instrument,
charging will start. During charging, the LED (red) is ON; the LED (green) is ON after the battery is fully charged.
Disconnect the power. It takes about 3 to 4 hours to charge. The input voltage of charger is 100 ~ 240V, 50/60Hz
AC, maximum current: 0.2A; output 5V DC, maximum charging current of about 500 mA. This instrument uses a
lithium polymer battery, no memory effect. You can charge at any time, and the tester can work normally during
charging.
Note: 1.If measure on charging station, please make sure that the connecting cable's place would not affect the
measurement operation.
2.Please charge as soon as possible during the low voltage situation, and cut off power as soon as possible
after full charge.
3.The battery switch is off when the instrument leave factory.
4.If the instrument work in-properly, and turn off / turn on the machine cannot help to solve the problem, then
please turn off the battery switch of the instrument backside, and restart after 10seconds.
2 Setting for initial usage
To use this instrument for the first time, the Clock Setting screen appears after booting. Press Left/Right to move
between items. Press Up/Down to adjust the time. After setting, press Enter to confirm and exit. The clock setting
is complete.
The following is the main screen, which appears after booting or before/after measuring. The main screen mainly